Correction of underquantification of human immunodeficiency virus type 1 load with the second version of the Roche Cobas AmpliPrep/Cobas TaqMan assay
- PMID: 20164284
- PMCID: PMC2849546
- DOI: 10.1128/JCM.01226-09
Correction of underquantification of human immunodeficiency virus type 1 load with the second version of the Roche Cobas AmpliPrep/Cobas TaqMan assay
Abstract
Initial evaluations of the Cobas AmpliPrep/Cobas TaqMan human immunodeficiency virus type 1 (HIV-1) test (CAP/CTM) demonstrated good performance but, afterwards, reports about underquantification were published. We investigated whether the problem was solved with a second version of this assay, the Cobas AmpliPrep/Cobas TaqMan HIV-1 test, version 2.0 (CAP/CTM v2.0). The remaining plasma of 375 consecutive HIV-1 positive samples with a viral load of >or=4,000 copies/ml was collected in three laboratories. The samples were diluted and retested with our routine method Cobas AmpliPrep/Cobas Amplicor HIV-1 monitor test v1.5 in ultrasensitive mode (CAP/CA PHS), as well as with the CAP/CTM and CAP/CTM v2.0 tests. An absolute difference between the results of two methods of >or=0.71 log(10) copies/ml was defined as moderately discrepant, and an absolute difference of >or=0.93 log(10) copies/ml was defined as severely discrepant. In addition, criteria for considering the new methods equivalent to the routine method were formulated. (i) For CAP/CTM compared to CAP/CA PHS, 36 (9.5%) and 20 (5.3%) samples were, respectively, considered moderately and severely underquantified by CAP/CTM. The mean difference between CAP/CTM and CAP/CA PHS was -0.32 log(10) copies/ml. Eight of nineteen of the severely underquantified samples were from patients infected with HIV-1 subtype B strain. (ii) For CAP/CTM v2.0 compared to CAP/CA PHS, no sample was moderately or severely underquantified by CAP/CTM v2.0. A mean difference of 0.08 log(10) copies/ml was found with CAP/CTM v2.0 compared to CAP/CA PHS. The underquantification problem of the CAP/CTM kit was clearly demonstrated. The criteria for the equivalence of CAP/CTM v2.0 to the routine test CAP/CA PHS were fulfilled.
Figures
References
-
- Alaeus, A., K. Lidman, A. Sonnerborg, and J. Albert. 1997. Subtype-specific problems with quantification of plasma HIV-1 RNA. AIDS 11:859-865. - PubMed
-
- Damond, F., C. Apetrei, D. Descamps, F. Brun-Vezinet, and F. Simon. 1999. HIV-1 subtypes and plasma RNA quantification. AIDS 13:286-288. - PubMed
-
- Damond, F., B. Roquebert, A. Benard, G. Collin, M. Miceli, P. Yeni, F. Brun-Vezinet, and D. Descamps. 2007. Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche Cobas Amplicor HIV-1 Monitor Version 1.5 and the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 assays. J. Clin. Microbiol. 45:3436-3438. - PMC - PubMed
-
- Debyser, Z., E. Van Wijngaerden, K. Van Laethem, K. Beuselinck, M. Reynders, E. De Clercq, J. Desmyter, and A. M. Vandamme. 1998. Failure to quantify viral load with two of the three commercial methods in a pregnant woman harboring an HIV type 1 subtype G strain. AIDS Res. Hum. Retrovir. 14:453-459. - PubMed
-
- Department of Health and Human Services. Guidelines for the use of antiretroviral agents in HIV-1-infected adults and adolescents. U.S. Department of Health and Human Services, Washington, DC. http://www.aidsinfo.nih.gov/contentfiles/adultandadolescentGL.pdf.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous