Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Apr;48(4):1354-7.
doi: 10.1128/JCM.01751-09. Epub 2010 Feb 17.

Performance of an agar dilution method and a Vitek 2 card for detection of inducible clindamycin resistance in Staphylococcus spp

Affiliations
Comparative Study

Performance of an agar dilution method and a Vitek 2 card for detection of inducible clindamycin resistance in Staphylococcus spp

Christian Lavallée et al. J Clin Microbiol. 2010 Apr.

Abstract

The D-zone test detects inducible clindamycin resistance in Staphylococcus spp. Two other methods not described by the Clinical and Laboratory Standards Institute (CLSI) are available to test for this resistance mechanism: an agar dilution method and new Vitek 2 cards. This study evaluated the performance of both methods in detecting inducible clindamycin resistance. Nonduplicate clinical strains of Staphylococcus spp. (111 Staphylococcus aureus and 52 coagulase-negative staphylococcus strains), intermediate or resistant to erythromycin but susceptible to clindamycin, were obtained from three hospitals in Montreal, Quebec, Canada. Molecular analysis to detect resistance genes was conducted on all strains. A Mueller-Hinton agar containing 1 mg of erythromycin and 0.5 mg of clindamycin/liter was used for the dilution method, and two inocula were tested: 10(4) and 10(5) CFU per spot. Plates were read at 24 and 48 h. The Vitek 2 AST-P580 card was used according to the manufacturer's recommendations. The results were compared to those of the D-zone test. The D-zone test was positive in 134 of 163 (82%) strains. With the 10(4) CFU inoculum, the sensitivities were 84 and 99% at 24 and 48 h, respectively. The 10(5) CFU inoculum increased the sensitivities at 24 and 48 h to 91 and 100%, respectively. The specificity was 100% for the 10(4) CFU inoculum at 24 h and 97% for the other combinations. The sensitivity and specificity for the Vitek 2 card were 93 and 100%, respectively. The performance of both the agar dilution method and the Vitek 2 card was good, but these methods were not as sensitive as the D-zone test at 24 h.

PubMed Disclaimer

Comment in

References

    1. Ajantha, G. S., R. D. Kulkarni, J. Shetty, C. Shubhada, and P. Jain. 2008. Phenotypic detection of inducible clindamycin resistance among Staphylococcus aureus isolates by using the lower limit of recommended inter-disk distance. Indian J. Pathol. Microbiol. 51:376-378. - PubMed
    1. Cetin, E. S., H. Gunes, S. Kaya, B. C. Aridogan, and M. Demirci. 2008. Macrolide-lincosamide-streptogramin B resistance phenotypes in clinical staphylococcal isolates. Int. J. Antimicrob. Agents 31:364-368. - PubMed
    1. CLSI. 2008. Performance standards for antimicrobial susceptibility testing: 18th informational supplement. CLSI document M100-S18. Clinical Laboratory Standards Institute, Wayne, PA.
    1. Daurel, C., C. Huet, A. Dhalluin, M. Bes, J. Etienne, and R. Leclercq. 2008. Differences in potential for selection of clindamycin-resistant mutants between inducible erm(A) and erm(C) Staphylococcus aureus genes. J. Clin. Microbiol. 46:546-550. - PMC - PubMed
    1. Fernandes, C. J., M. V. N. O'Sullivan, Y. Cai, F. Kong, X. Zeng, G. L. Gilbert, and G. Kotsiou. 2007. Agar dilution method for detection of inducible clindamycin resistance in Staphylococcus spp. J. Clin. Microbiol. 45:4018-4020. - PMC - PubMed

Publication types