Purpose: To investigate the occurrence and features of the atypical birefringence pattern (ABP) images in scanning laser polarimetry with variable corneal compensation (GD×VCC) in healthy children and to assess their impact on the values of the retinal nerve fiber layer (RNFL) thickness.
Methods: GD×VCC scans in 120 healthy white school-aged children with mean age ± standard deviation (SD) 12.85 ± 3.0 years were evaluated using typical scan score (TSS) calculation and by subjective grading of the scans. Statistical analysis including the impact of ABP on the RNFL thickness in GD × VCC Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was done.
Results: The ABP was found in 18 out of 120 patients (15%) at cut-off value of TSS <80. Subjective evaluation of the scans raised the frequency of ABP to 20% of patients. The mean ± SD values of TSNIT Average, Superior Average, and Inferior Average in 26 eyes with ABP versus 214 eyes with normal birefringence pattern were 66.99 ± 7.29 μm versus 58.00 ± 6.22 μm (P = 7.2E to -11), 78.43 ± 9.27 μm versus 72.33 ± 8.72 μm (P = 0.001) and 80.87 ± 12.01 μm versus 70.00 ± 10.20 μm (P = 0.000001), respectively. The same comparison in TSNIT SD showed minimal difference and was 25.42 ± 5.84 μm versus 26.41 ± 4.81 μm (P = 0.41).
Conclusions: The occurrence of ABP in children is not rare and may significantly distort the measured values of the RNFL thickness in TSNIT parameters using GD × VCC.
Similar articles
-
Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation.Am J Ophthalmol. 2005 Mar;139(3):437-46. doi: 10.1016/j.ajo.2004.10.019. Am J Ophthalmol. 2005. PMID: 15767051
-
Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.Ophthalmology. 2007 Nov;114(11):1988-93. doi: 10.1016/j.ophtha.2007.01.022. Epub 2007 Apr 24. Ophthalmology. 2007. PMID: 17459481
-
The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children.Acta Ophthalmol. 2012 Dec;90(8):709-12. doi: 10.1111/j.1755-3768.2011.02133.x. Epub 2011 Mar 18. Acta Ophthalmol. 2012. PMID: 21418149
-
Scanning laser polarimetry with enhanced corneal compensation and optical coherence tomography in normal and glaucomatous eyes.Invest Ophthalmol Vis Sci. 2007 May;48(5):2099-104. doi: 10.1167/iovs.06-1087. Invest Ophthalmol Vis Sci. 2007. PMID: 17460267
-
Peripapillary retinal nerve fiber layer thickness analysis with scanning laser polarimetry (GDx VCC) in normal children.J Glaucoma. 2010 Jan;19(1):51-7. doi: 10.1097/IJG.0b013e3181a2fa61. J Glaucoma. 2010. PMID: 19373102
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources