Photoplethysmography. Part 1. Comparison with laser Doppler flowmetry
- PMID: 2016919
- DOI: 10.1007/BF02446294
Photoplethysmography. Part 1. Comparison with laser Doppler flowmetry
Abstract
Photoplethysmography (PPG) and laser Doppler flowmetry (LDF) were compared and evaluated. The comparison was accomplished considering differences in physical principles and geometrical and optical conditions. Changes in human skin perfusion were induced by cold and hot water provocation on limited areas of the finger and the forearm. The results showed that LDF and PPG, using red light at 630-660 nm and a commercial PPG probe, were in general equally sensitive in detecting a blood perfusion increase following a skin temperature elevation. However, we also found that PPG occasionally showed an inverse response to a skin temperature elevation, especially in finger skin. Furthermore, the study indicated that laser light is unsuitable as a light source in PPG using optical fibres of small diameter and with no fibre separation. It was also found that the physical dimensions of the probe (including the light source and photodetector) play an important role in determining the measuring volume and the quality of the signal.
Comment in
-
Photoplethysmograph from a laser source.Med Biol Eng Comput. 1991 Sep;29(5):564. doi: 10.1007/BF02442333. Med Biol Eng Comput. 1991. PMID: 1817224 No abstract available.
Similar articles
-
Photoplethysmography. Part 2. Influence of light source wavelength.Med Biol Eng Comput. 1991 Jan;29(1):48-54. doi: 10.1007/BF02446295. Med Biol Eng Comput. 1991. PMID: 2016920
-
A technique based on laser Doppler flowmetry and photoplethysmography for simultaneously monitoring blood flow at different tissue depths.Med Biol Eng Comput. 2010 May;48(5):415-22. doi: 10.1007/s11517-010-0577-2. Epub 2010 Jan 28. Med Biol Eng Comput. 2010. PMID: 20107915
-
Response of skin photoplethysmography, laser Doppler flowmetry and transcutaneous oxygen tensiometry to stenosis-induced reductions in limb blood flow.Eur J Vasc Surg. 1989 Apr;3(2):113-20. doi: 10.1016/s0950-821x(89)80005-2. Eur J Vasc Surg. 1989. PMID: 2653874
-
[Methods of microcirculatory monitoring (laser Doppler flowmetry, photoplethysmography and computer-assisted venous occlusion plethysmography)].Anasthesiol Intensivmed Notfallmed Schmerzther. 1996 May;31(1 Suppl):S37-43. Anasthesiol Intensivmed Notfallmed Schmerzther. 1996. PMID: 8737539 Review. German. No abstract available.
-
[The status of laser Doppler examination in patients with arterial occlusive disease].Herz. 1988 Dec;13(6):382-91. Herz. 1988. PMID: 3061920 Review. German.
Cited by
-
Photoplethysmograph from a laser source.Med Biol Eng Comput. 1992 Sep;30(5):568. doi: 10.1007/BF02457840. Med Biol Eng Comput. 1992. PMID: 1293451 No abstract available.
-
Correction for pulse height variability reduces physiological noise in functional MRI when studying spontaneous brain activity.Hum Brain Mapp. 2010 Feb;31(2):311-25. doi: 10.1002/hbm.20866. Hum Brain Mapp. 2010. PMID: 19662656 Free PMC article.
-
Photoplethysmography. Part 2. Influence of light source wavelength.Med Biol Eng Comput. 1991 Jan;29(1):48-54. doi: 10.1007/BF02446295. Med Biol Eng Comput. 1991. PMID: 2016920
-
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors.Biosensors (Basel). 2020 May 28;10(6):56. doi: 10.3390/bios10060056. Biosensors (Basel). 2020. PMID: 32481598 Free PMC article. Review.
-
Innovative measurement of routine physiological variables (heart rate, respiratory rate and oxygen saturation) using a remote photoplethysmography imaging system: a prospective comparative trial protocol.BMJ Open. 2021 Aug 13;11(8):e047896. doi: 10.1136/bmjopen-2020-047896. BMJ Open. 2021. PMID: 34389569 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources