Test compounds for detecting the silanol effect on the elution of ionized amines in reversed-phase LC
- PMID: 20169553
- DOI: 10.1002/jssc.200900760
Test compounds for detecting the silanol effect on the elution of ionized amines in reversed-phase LC
Erratum in
- J Sep Sci. 2010 Apr;33(8):1174
Abstract
The effectiveness of several basic compounds for testing silica-based stationary phases was reviewed by applying them to recent columns for reversed-phase HPLC. Most octadecylsilylated (C18) stationary phases, prepared as a base-deactivated material from high-purity silica gel with endcapping, provided excellent peak shape and column efficiency for the bases including benzylamine and amitriptyline that once caused problems and were subsequently employed for testing silanol activities. However, a cyclic tertiary amine, dextrometorphan, was eluted as an acceptable peak from only a few columns at neutral pH. Such a more sensitive probe is expected to contribute to further improvement of the stationary phase for reversed-phase HPLC.
Similar articles
-
Kinetic performance of reversed-phase C18 high-performance liquid chromatography columns compared by means of the Kinetic Plot Method in pharmaceutically relevant applications.J Chromatogr A. 2011 May 27;1218(21):3351-9. doi: 10.1016/j.chroma.2010.08.071. Epub 2010 Sep 20. J Chromatogr A. 2011. PMID: 20863506
-
Synthesis and characterization of novel polar-embedded silica stationary phases for use in reversed-phase high-performance liquid chromatography.J Chromatogr A. 2013 Jan 4;1271(1):153-62. doi: 10.1016/j.chroma.2012.11.045. Epub 2012 Nov 26. J Chromatogr A. 2013. PMID: 23237708
-
Effect of trimethylsilane pre-capping on monomeric C18 stationary phases made from high-purity type-B silica substrates: efficiency, retention, and stability.J Chromatogr A. 2012 Jan 13;1220:35-43. doi: 10.1016/j.chroma.2011.11.041. Epub 2011 Nov 25. J Chromatogr A. 2012. PMID: 22176738
-
Preparation of monolithic silica columns for high-performance liquid chromatography.J Chromatogr A. 2008 May 16;1191(1-2):231-52. doi: 10.1016/j.chroma.2008.02.029. Epub 2008 Feb 13. J Chromatogr A. 2008. PMID: 18313061 Review.
-
An appraisal of the chemical and thermal stability of silica based reversed-phase liquid chromatographic stationary phases employed within the pharmaceutical environment.J Pharm Biomed Anal. 2013 Apr 15;77:100-15. doi: 10.1016/j.jpba.2013.01.013. Epub 2013 Jan 11. J Pharm Biomed Anal. 2013. PMID: 23411003 Review.
Cited by
-
A Novel Bisquaternary Ammonium Compound as an Anion Sensor-ESI-MS and Fluorescence Study.Int J Mol Sci. 2024 Mar 19;25(6):3467. doi: 10.3390/ijms25063467. Int J Mol Sci. 2024. PMID: 38542440 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources