Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Mar;94(3):300-6.
doi: 10.1016/j.radonc.2009.12.043. Epub 2010 Feb 18.

Simultaneous integrated boost in breast conserving treatment of breast cancer: a dosimetric comparison of helical tomotherapy and three-dimensional conformal radiotherapy

Affiliations
Comparative Study

Simultaneous integrated boost in breast conserving treatment of breast cancer: a dosimetric comparison of helical tomotherapy and three-dimensional conformal radiotherapy

Tarek Hijal et al. Radiother Oncol. 2010 Mar.

Abstract

Background and purpose: To evaluate the dosimetry of helical tomotherapy (HT) and three-dimensional conformal radiotherapy (3D-CRT) in breast cancer patients undergoing whole breast radiation with simultaneous integrated boost (SIB) of the tumor bed.

Material and methods: Thirteen patients with breast cancer treated by lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned using both HT and 3D-CRT using the field-in-field technique. The whole breast and tumor bed were prescribed 50.68 Gy and 64.4 Gy, respectively, in 28 fractions. Dosimetries for both techniques were compared.

Results: Coverage of the whole breast was adequate with both techniques (V(95%)=96.22% vs. 96.25%, with HT and 3D-CRT, respectively; p=0.64). Adequate tumor bed coverage was also achieved, although it was significantly lower with HT (V(95%)=97.18% vs. 99.72%; p<0.001). Overdose of the breast volume outside the tumor bed was significantly lower with HT (V(54.23 Gy)=12.47% vs. 30.83%; p<0.001). Ipsilateral lung V(20 Gy) (6.34% vs. 10.17%; p<0.001), V(5 Gy) (16.54% vs. 18.53%; p<0.05) and mean dose (4.05 Gy vs. 6.36 Gy; p<0.001) were significantly lower with HT. In patients with left-sided tumors, heart V(30 Gy) (0.03% vs. 1.14%; p<0.05) and mean dose (1.35 Gy vs. 2.22 Gy; p<0.01) were significantly lower with HT, but not V(5 Gy). Contralateral breast V(5 Gy) (0.27% vs. 0.00%; p<0.01) and maximum dose were significantly increased with HT.

Conclusions: In breast cancer treated with SIB, both HT and 3D-CRT provided adequate target volume coverage and low heart doses. Tumor bed coverage was slightly lower with HT, but HT avoided unnecessary breast overdosage while improving ipsilateral lung dosimetry.

PubMed Disclaimer

Publication types