Hydrodynamic gating valve for microfluidic fluorescence-activated cell sorting
- PMID: 20172088
- DOI: 10.1016/j.aca.2010.01.046
Hydrodynamic gating valve for microfluidic fluorescence-activated cell sorting
Abstract
Microfluidic cell sorter allows efficient separation of small number of cells, which is beneficial in handling cells, especially primary cells that cannot be expanded to large populations. Here, we demonstrate a microfluidic fluorescence-activated cell sorter (muFACS) with a novel sorting mechanism, in which automatic on-chip sorting is realized by turning on/off the hydrodynamic gating valve when a fluorescent target is detected. Formation of the hydrodynamic gating valve was investigated by both numerical simulation and flow visualization experiment. Separation of fluorescent polystyrene beads was then conducted to evaluate this sorting mechanism and to optimize the separation conditions. Isolation of fluorescent HeLa-DsRed cells was further demonstrated with high purity and recovery rate. Viability of the sorted cells was also examined, suggesting a survival rate of more than 90%. We expect this sorting approach to find widespread applications in bioanalysis.
Copyright 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Integrating advanced functionality in a microfabricated high-throughput fluorescent-activated cell sorter.Lab Chip. 2003 Feb;3(1):22-7. doi: 10.1039/b209333b. Epub 2003 Jan 23. Lab Chip. 2003. PMID: 15100801
-
Fluorescence-activated droplet sorting (FADS): efficient microfluidic cell sorting based on enzymatic activity.Lab Chip. 2009 Jul 7;9(13):1850-8. doi: 10.1039/b902504a. Epub 2009 Apr 23. Lab Chip. 2009. PMID: 19532959
-
Computer simulations of the energy dissipation rate in a fluorescence-activated cell sorter: Implications to cells.Biotechnol Bioeng. 2008 Jun 1;100(2):260-72. doi: 10.1002/bit.21762. Biotechnol Bioeng. 2008. PMID: 18078288
-
Microfluidic impedance-based flow cytometry.Cytometry A. 2010 Jul;77(7):648-66. doi: 10.1002/cyto.a.20910. Cytometry A. 2010. PMID: 20583276 Review.
-
Microfluidics for flow cytometric analysis of cells and particles.Physiol Meas. 2005 Jun;26(3):R73-98. doi: 10.1088/0967-3334/26/3/R02. Epub 2005 Feb 1. Physiol Meas. 2005. PMID: 15798290 Review.
Cited by
-
Effect of Varying Expression of EpCAM on the Efficiency of CTCs Detection by SERS-Based Immunomagnetic Optofluidic Device.Cancers (Basel). 2020 Nov 10;12(11):3315. doi: 10.3390/cancers12113315. Cancers (Basel). 2020. PMID: 33182636 Free PMC article.
-
Rapid isolation of rare targets from large fluid volumes.Sci Rep. 2020 Jul 27;10(1):12458. doi: 10.1038/s41598-020-69315-1. Sci Rep. 2020. PMID: 32719382 Free PMC article.
-
Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation.Lab Chip. 2015 Mar 7;15(5):1230-49. doi: 10.1039/c4lc01246a. Lab Chip. 2015. PMID: 25598308 Free PMC article. Review.
-
A Unidirectional Cell Switching Gate by Engineering Grating Length and Bending Angle.PLoS One. 2016 Jan 28;11(1):e0147801. doi: 10.1371/journal.pone.0147801. eCollection 2016. PLoS One. 2016. PMID: 26821058 Free PMC article.
-
Standing Surface Acoustic Wave (SSAW)-Based Fluorescence-Activated Cell Sorter.Small. 2018 Oct;14(40):e1801996. doi: 10.1002/smll.201801996. Epub 2018 Aug 31. Small. 2018. PMID: 30168662 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources