Measurement of particle flux in a static matrix with suppressed influence of optical properties, using low coherence interferometry
- PMID: 20174114
- DOI: 10.1364/OE.18.002849
Measurement of particle flux in a static matrix with suppressed influence of optical properties, using low coherence interferometry
Abstract
Perfusion measurements using conventional laser Doppler techniques are affected by the variations in tissue optical properties. Differences in absorption and scattering will induce different path lengths and consequently will alter the probability that a Doppler shift will occur. In this study, the fraction of Doppler shifted photons and the Doppler broadening of a dynamic medium, are measured with a phase modulated low coherence Mach-Zehnder interferometer. Path length-resolved dynamic light scattering measurements are performed in various media having a constant concentration of dynamic particles inside a static matrix with different scattering properties and the results are compared with a conventional laser Doppler technique, with a simple model and with Monte Carlo simulations. We demonstrate that, for larger optical path lengths, the scattering coefficient of the static matrix in which the moving particles are embedded have a small to minimal effect on the measured fraction of Doppler shifted photons and on the measured average Doppler frequency of the Doppler shifted light. This approach has potential applications in measuring perfusion independent of the influence of optical properties in the static tissue matrix.
Similar articles
-
Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light.Rev Sci Instrum. 2007 Dec;78(12):126103. doi: 10.1063/1.2823558. Rev Sci Instrum. 2007. PMID: 18163752
-
Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry.J Biomed Opt. 2007 Mar-Apr;12(2):024020. doi: 10.1117/1.2714795. J Biomed Opt. 2007. PMID: 17477735
-
In vivo optical path lengths and path length resolved doppler shifts of multiply scattered light.Lasers Surg Med. 2010 Nov;42(9):692-700. doi: 10.1002/lsm.20969. Lasers Surg Med. 2010. PMID: 20976809 Clinical Trial.
-
Implantable hearing device performance measured by laser Doppler interferometry.Ear Nose Throat J. 1997 May;76(5):297-9, 302, 305-9. Ear Nose Throat J. 1997. PMID: 9170711 Review.
-
Review of Monte Carlo modeling of light transport in tissues.J Biomed Opt. 2013 May;18(5):50902. doi: 10.1117/1.JBO.18.5.050902. J Biomed Opt. 2013. PMID: 23698318 Review.
Cited by
-
Laser speckle imaging in the spatial frequency domain.Biomed Opt Express. 2011 Jun 1;2(6):1553-63. doi: 10.1364/BOE.2.001553. Epub 2011 May 13. Biomed Opt Express. 2011. PMID: 21698018 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources