Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Mar;41(3):279-84.
doi: 10.1016/j.injury.2009.09.012.

Systematic effects of surgical treatment of hip fractures: gliding screw-plating vs intramedullary nailing

Affiliations
Randomized Controlled Trial

Systematic effects of surgical treatment of hip fractures: gliding screw-plating vs intramedullary nailing

Dionysios-Alexandros J Verettas et al. Injury. 2010 Mar.

Abstract

Aim: Numerous studies have been published regarding the comparison between intramedullary nail and the dynamic hip screw and plate for the fixation of intertrochanteric fractures in elderly patients. In this paper we present a comparative study of these two methods regarding their systemic effects on this group of patients.

Materials-methods: This is a randomized trial of 120 consecutive patients with an intertrochanteric fracture treated with either extramedullary fixation (dynamic hip screw and plate; DHS, Synthes-Stratec, Oberdorf, Switzerland) or intramedullary nail (Gamma nail, Stryker Howmedica, Freiburg, Germany and Endovis BA, Citieffe, Bologna, Italy). The parameters that we assessed pre-operatively, in addition to their demographics, included their mental state (MMSE), their nutritional and immune state and their pulmonary function. Intra-operatively we calculated the amount of radiation exposure, the amount of blood loss and the length of operative time for each procedure. Postoperatively we repeated the calculation of the mental and pulmonary state and the blood loss, during days 1, 3, and 10 and related them to the ease of the patient's mobilization.

Results: Decreased bleeding and post-operative pain, reduced post-operative morbidity and faster recovery of function were better but not significant in the group of intramedullary fixation (all p>0.05). However, in the same group there were slightly more patients in whom the MMSE was falling, together with their pulmonary function, suggesting that this method probably predisposes to higher chances of pulmonary dysfunction and the possibility of pulmonary embolism.

Conclusion: We found no significant differences between the two methods of stabilization of these fractures regarding their systemic effects perioperatively. The classic dynamic hip screw can preserve its position as a safe and effective solution for these already vulnerable patients having sustained a trochanteric fracture against the novel intramedullary techniques.