Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Jun;28(1):39-44.
doi: 10.1007/s10840-010-9468-6. Epub 2010 Feb 23.

Efficacy of bundle ablation for cavotricuspid isthmus-dependent atrial flutter: combination of the maximum voltage-guided ablation technique and high-density electro-anatomical mapping

Affiliations
Randomized Controlled Trial

Efficacy of bundle ablation for cavotricuspid isthmus-dependent atrial flutter: combination of the maximum voltage-guided ablation technique and high-density electro-anatomical mapping

Hirokazu Sato et al. J Interv Card Electrophysiol. 2010 Jun.

Abstract

Introduction: Pathological studies have demonstrated that the cavotricuspid isthmus (CTI) is often composed of discrete muscle bundles, which are thought to be represented electrically as high-amplitude electrograms. Based on this observation, we visualized the bundles using an electro-anatomical mapping system (EAMS) and investigate the efficacy of bundle ablation which is an ablation method for selectively targeting high-voltage sites obtained by high-density electro-anatomical mapping along the CTI.

Methods: Sixty patients with atrial flutter were randomly assigned to cavotricuspid isthmus ablation using a conventional anatomical approach (Group 1) or bundle ablation approach (Group 2). In Group 2, CTI was mapped in detail with EAMS, and we visualized the bundles that were 1.5 mV or more on a bipolar voltage map. Radiofrequency (RF) ablation was delivered sequentially from the maximum voltage site at the shortest distance of the bundle until bidirectional block was achieved.

Results: Bidirectional block was achieved in all patients. Mean ablation times (Group 1, 1,392 + or - 960 s; Group 2, 638 + or - 342 s, p < 0.01), the mean number of RF applications (Group 1, 31.7 + or - 23.6; Group 2, 13.0 + or - 7.0, p < 0.01), and fluoroscopy times (Group 1, 50.4 + or - 28.3 min; Group 2, 42.3 + or - 21.3 min, p < 0.01) were significantly shorter in Group 2 than those in Group 1.

Conclusion: Bundle ablation at CTI is highly effective for achieving a bidirectional block requiring shorter ablation times, shorter fluoroscopy times, and fewer RF applications.

PubMed Disclaimer

References

    1. J Cardiovasc Electrophysiol. 2007 Jan;18(1):18-22 - PubMed
    1. J Am Coll Cardiol. 2000 Jun;35(7):1898-904 - PubMed
    1. J Cardiovasc Electrophysiol. 2000 Jan;11(1):90-4 - PubMed
    1. J Cardiovasc Electrophysiol. 2009 Jul;20(7):734-40 - PubMed
    1. J Cardiovasc Electrophysiol. 2007 Jun;18(6):612-6 - PubMed

Publication types

MeSH terms

LinkOut - more resources