. 2010 Jun;29(2):77-90.
doi: 10.3109/15569521003587327.

An interlaboratory study of the short time exposure (STE) test using SIRC cells for predicting eye irritation potential

Affiliations

An interlaboratory study of the short time exposure (STE) test using SIRC cells for predicting eye irritation potential

Yutaka Takahashi et al. Cutan Ocul Toxicol. 2010 Jun.

Abstract

We have developed the short time exposure (STE) test using a rabbit corneal cell line (SIRC cells) as an alternative eye irritation test. The STE test uses relative viability as the endpoint after cells are exposed to the test material at 5%, 0.5%, and 0.05% concentrations for 5 minutes. In this interlaboratory study, 2 laboratories conducted the test using 70 raw materials in order to evaluate transferability, between-laboratory reproducibility, and predictive capacity of the STE test as an alternative eye irritation test. Transferability was assessed using saline as a negative control and 0.01% sodium lauryl sulfate as a positive control. The relative viabilities obtained for the 2 laboratories were almost the same. Therefore, transferability was considered to be excellent. The 2 laboratories showed similar relative viabilities for all 70 raw materials at each test concentration. The correspondence rates of the eye irritation categories (irritants and nonirritants) were over 97% for each concentration tested, exhibiting high between-laboratory reproducibility. The correspondence rates for predicting eye irritation potential of undiluted raw materials and a diluted solution (10%) were over 85% at each laboratory for the 5% and 0.05% test concentrations in the STE. Lastly, the correspondence rate for the rank classification by the STE test prediction model at each laboratory was over 72%, and the correspondence rate became almost 90% when acids, amines, and alcohols were excluded from the analysis. From the above data, excellent transferability, high between-laboratory reproducibility, and high predictive capacity of the STE test were observed in the interlaboratory study by 2 laboratories.

PubMed Disclaimer