Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives
- PMID: 20185659
- DOI: 10.1213/ANE.0b013e3181cc885a
Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives
Abstract
The ability to monitor cardiac output is one of the important cornerstones of hemodynamic assessment for managing critically ill patients at increased risk for developing cardiac complications, and in particular in patients with preexisting cardiovascular comorbidities. For >30 years, single-bolus thermodilution measurement through a pulmonary artery catheter for assessment of cardiac output has been widely accepted as the "clinical standard" for advanced hemodynamic monitoring. In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying technical principles and the unique features but also the limitations of each application of indicator dilution are outlined.
Comment in
-
Continuous thermodilution cardiac output monitoring during therapeutic hypothermia.Anesth Analg. 2011 Jan;112(1):250-1. doi: 10.1213/ANE.0b013e3181f33910. Anesth Analg. 2011. PMID: 21173213 No abstract available.
Similar articles
-
[Hemodynamic monitoring in the intensive care unit: pulmonary artery catheter versus PiCCO].Dtsch Med Wochenschr. 2011 Feb;136(8):376-80. doi: 10.1055/s-0031-1272539. Epub 2011 Feb 17. Dtsch Med Wochenschr. 2011. PMID: 21332037 Review. German.
-
Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology.Acta Anaesthesiol Scand. 2004 May;48(5):658-61. doi: 10.1111/j.1399-6576.2004.00375.x. Acta Anaesthesiol Scand. 2004. PMID: 15101866
-
Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system.Clin Intensive Care. 1994;5(2):52-5. Clin Intensive Care. 1994. PMID: 10147254
-
Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.Int J Nurs Stud. 2009 Oct;46(10):1291-7. doi: 10.1016/j.ijnurstu.2009.03.013. Epub 2009 May 6. Int J Nurs Stud. 2009. PMID: 19423107
-
Non-invasive cardiac output monitoring.Intensive Crit Care Nurs. 2004 Apr;20(2):103-8. doi: 10.1016/j.iccn.2004.01.002. Intensive Crit Care Nurs. 2004. PMID: 15072778 Review.
Cited by
-
Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters.Crit Care. 2012 May 30;16(3):R98. doi: 10.1186/cc11366. Crit Care. 2012. PMID: 22647561 Free PMC article. Clinical Trial.
-
Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis.Crit Care. 2021 Mar 29;25(1):125. doi: 10.1186/s13054-021-03523-7. Crit Care. 2021. PMID: 33781307 Free PMC article.
-
Transit Time Measurement in Indicator Dilution Curves: Overcoming the Missing Ground Truth and Quantifying the Error.Front Physiol. 2021 May 28;12:588120. doi: 10.3389/fphys.2021.588120. eCollection 2021. Front Physiol. 2021. PMID: 34122123 Free PMC article.
-
Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.J Clin Monit Comput. 2015 Dec;29(6):789-800. doi: 10.1007/s10877-015-9668-9. Epub 2015 Feb 15. J Clin Monit Comput. 2015. PMID: 25682204 Free PMC article.
-
Pulse pressure and end-tidal carbon dioxide for monitoring low native cardiac output during veno-arterial ECLS: a prospective observational study.Crit Care. 2020 Sep 22;24(1):569. doi: 10.1186/s13054-020-03280-z. Crit Care. 2020. PMID: 32962727 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical