Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Sep;18(9):1845-51.
doi: 10.1038/oby.2010.34. Epub 2010 Feb 25.

Estimation of free-living energy expenditure using a novel activity monitor designed to minimize obtrusiveness

Affiliations
Free article

Estimation of free-living energy expenditure using a novel activity monitor designed to minimize obtrusiveness

Alberto G Bonomi et al. Obesity (Silver Spring). 2010 Sep.
Free article

Abstract

The aim of this study was to investigate the ability of a novel activity monitor designed to be minimally obtrusive in predicting free-living energy expenditure. Subjects were 18 men and 12 women (age: 41 +/- 11 years, BMI: 24.4 +/- 3 kg/m(2)). The habitual physical activity was monitored for 14 days using a DirectLife triaxial accelerometer for movement registration (Tracmor(D)) (Philips New Wellness Solutions, Lifestyle Incubator, the Netherlands). Tracmor(D) output was expressed as activity counts per day (Cnts/d). Simultaneously, total energy expenditure (TEE) was measured in free living conditions using doubly labeled water (DLW). Activity energy expenditure (AEE) and the physical activity level (PAL) were determined from TEE and sleeping metabolic rate (SMR). A multiple-linear regression model predicted 76% of the variance in TEE, using as independent variables SMR (partial-r(2) = 0.55, P < 0.001), and Cnts/d (partial r(2) = 0.21, P < 0.001). The s.e. of TEE estimates was 0.9 MJ/day or 7.4% of the average TEE. A model based on body mass (partial-r(2) = 0.31, P < 0.001) and Cnts/d (partial-r(2) = 0.23, P < 0.001) predicted 54% of the variance in TEE. Cnts/d were significantly and positively associated with AEE (r = 0.54, P < 0.01), PAL (r = 0.68, P < 0.001), and AEE corrected by body mass (r = 0.71, P < 0.001). This study showed that the Tracmor(D) is a highly accurate instrument for predicting free-living energy expenditure. The miniaturized design did not harm the ability of the instrument in measuring physical activity and in determining outcome parameters of physical activity such as TEE, AEE, and PAL.

PubMed Disclaimer

Publication types

LinkOut - more resources