Compensation of breathing motion artifacts for MRI with continuously moving table
Abstract
Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic. In this study, a technique for the reduction of breathing-motion artifacts for MRI with continuously moving table is presented, which reconstructs motion-consistent volumes from data acquired during free breathing. Axial images are acquired rapidly compared to the period of the breathing motion and consistently combined using a combination of rigid and nonrigid slice-to-volume registration. This new technique is compared to a previously reported artifact reduction method for MRI with continuously moving table that is based on the same acquisition scheme. While the latter method only suppresses ghosting artifacts, the new technique is shown to additionally reduce blurring, misregistrations, and signal cancellations in the reconstructed images.
(c) 2010 Wiley-Liss, Inc.
Similar articles
-
Temporally constrained respiratory gating improves continuously moving table MRI during free breathing.J Magn Reson Imaging. 2013 Jul;38(1):198-205. doi: 10.1002/jmri.23964. Epub 2012 Dec 12. J Magn Reson Imaging. 2013. PMID: 23239532
-
Novel reconstruction method for three-dimensional axial continuously moving table whole-body magnetic resonance imaging featuring autocalibrated parallel imaging GRAPPA.Magn Reson Med. 2009 Apr;61(4):867-73. doi: 10.1002/mrm.21859. Magn Reson Med. 2009. PMID: 19189291
-
Motion corrected compressed sensing for free-breathing dynamic cardiac MRI.Magn Reson Med. 2013 Aug;70(2):504-16. doi: 10.1002/mrm.24463. Epub 2012 Aug 16. Magn Reson Med. 2013. PMID: 22899104
-
Motion artifacts in MRI: A complex problem with many partial solutions.J Magn Reson Imaging. 2015 Oct;42(4):887-901. doi: 10.1002/jmri.24850. Epub 2015 Jan 28. J Magn Reson Imaging. 2015. PMID: 25630632 Free PMC article. Review.
-
Continuously moving table MRI in oncology.Rofo. 2010 Nov;182(11):954-64. doi: 10.1055/s-0029-1245727. Epub 2010 Oct 4. Rofo. 2010. PMID: 20922644 Review.
Cited by
-
Continuous Critical Respiratory Parameter Measurements Using a Single Low-Cost Relative Humidity Sensor: Evaluation Study.JMIR Biomed Eng. 2023 Oct 25;8:e47146. doi: 10.2196/47146. JMIR Biomed Eng. 2023. PMID: 38875670 Free PMC article.
-
Respiratory motion-corrected T1 mapping of the abdomen.MAGMA. 2024 Aug;37(4):637-649. doi: 10.1007/s10334-024-01196-1. Epub 2024 Aug 12. MAGMA. 2024. PMID: 39133420 Free PMC article.
-
Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP.Magn Reson Med. 2019 Nov;82(5):1631-1645. doi: 10.1002/mrm.27834. Epub 2019 Jun 10. Magn Reson Med. 2019. PMID: 31183892 Free PMC article.
-
Spatial lung imaging in clinical and translational settings.Breathe (Sheff). 2024 Oct 1;20(3):230224. doi: 10.1183/20734735.0224-2023. eCollection 2024 Oct. Breathe (Sheff). 2024. PMID: 39360023 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical