Anterior segment optical coherence tomography evaluation of the integrity of clear corneal incisions: a comparison between 2.2-mm and 2.65-mm main incisions
- PMID: 20189160
- DOI: 10.1016/j.ajo.2009.12.008
Anterior segment optical coherence tomography evaluation of the integrity of clear corneal incisions: a comparison between 2.2-mm and 2.65-mm main incisions
Abstract
Purpose: To compare wound characteristics and integrity of the 2.2-mm and 2.65-mm clear corneal incisions.
Design: Prospective, randomized clinical trial.
Methods: Patients undergoing phacoemulsification with lens implant were randomized to receive a 2.2-mm or 2.65-mm temporal clear corneal incision. The incisions were evaluated at 2, 24, and 96 hours for gape and wound architecture using anterior segment optical coherence tomography and for integrity using the Seidel test. Squareness of an incision was calculated (ratio of the incision length to the width).
Results: There were 30 patients in each group. Both incision sizes were watertight, although a mild internal main wound gape was detected on anterior segment optical coherence tomography in 35 eyes (58.3%) at 2 hours. The smaller wound was more square (0.81; standard deviation [SD], 0.11) than the larger wound (0.62; SD, 0.08; P < .001, t test). The mean squareness of eyes without wound gape at 2 hours (0.66; SD, 0.11) was lower than those with a wound gape (0.75; SD, 0.14; P = .008). A squareness factor of 0.72 or more had a positive predictive value for presence of wound gape at 2 hours of 79.3% and a negative predictive value of 61.3%. One side port incision with squareness of 1.39 had a mild leak at 2 and 24 hours, but no gape was seen on anterior segment optical coherence tomography.
Conclusions: Both the 2.2-mm and 2.65-mm clear corneal incisions clinically were competent, but the side port incision may leak. A truly square wound has a greater likelihood of being associated with internal wound gape at 2 hours after surgery, especially if the squareness factor is 0.72 or more.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Early changes in clear cornea incision after phacoemulsification: an anterior segment optical coherence tomography study.Acta Ophthalmol. 2009 Nov;87(7):764-8. doi: 10.1111/j.1755-3768.2008.01333.x. Epub 2009 Jun 22. Acta Ophthalmol. 2009. PMID: 19548882
-
In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.J Cataract Refract Surg. 2009 Mar;35(3):444-50. doi: 10.1016/j.jcrs.2008.11.034. J Cataract Refract Surg. 2009. PMID: 19251136
-
Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomography.J Cataract Refract Surg. 2007 Aug;33(8):1429-35. doi: 10.1016/j.jcrs.2007.04.011. J Cataract Refract Surg. 2007. PMID: 17662437
-
Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems.Ophthalmology. 2005 Jan;112(1):58-66. doi: 10.1016/j.ophtha.2004.06.030. Ophthalmology. 2005. PMID: 15629821 Review.
-
Practical applications of anterior segment optical coherence tomography imaging following corneal surgery.Semin Ophthalmol. 2012 Sep-Nov;27(5-6):125-32. doi: 10.3109/08820538.2012.707274. Semin Ophthalmol. 2012. PMID: 23163266 Review.
Cited by
-
Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.Eye (Lond). 2014 Oct;28(10):1174-8. doi: 10.1038/eye.2014.162. Epub 2014 Jul 18. Eye (Lond). 2014. PMID: 25033901 Free PMC article. Clinical Trial.
-
Using Optical Coherence Tomography in the Management of Postoperative Wound Leaks After Cataract Surgery.Fed Pract. 2019 Aug;36(8):356-364. Fed Pract. 2019. PMID: 31456626 Free PMC article.
-
Different-sized incisions for phacoemulsification in age-related cataract.Cochrane Database Syst Rev. 2017 Sep 20;9(9):CD010510. doi: 10.1002/14651858.CD010510.pub2. Cochrane Database Syst Rev. 2017. PMID: 28931202 Free PMC article.
-
Relationship between early structural changes at cornea incision sites and surgical outcomes after phacoemulsification.Int J Ophthalmol. 2019 Jul 18;12(7):1139-1145. doi: 10.18240/ijo.2019.07.14. eCollection 2019. Int J Ophthalmol. 2019. PMID: 31341805 Free PMC article.
-
Seidel and India ink tests assessment of different clear cornea side-port incision configurations.Graefes Arch Clin Exp Ophthalmol. 2013 Aug;251(8):1961-5. doi: 10.1007/s00417-013-2380-x. Epub 2013 May 24. Graefes Arch Clin Exp Ophthalmol. 2013. PMID: 23702930
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources