Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group
- PMID: 20189513
- DOI: 10.1016/j.gie.2009.12.021
Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group
Abstract
Background: Colonoscopy has been adopted as the preferred method to screen for colorectal neoplasia in the United States. However, lesions can be missed because of numerous factors, including location on the proximal aspect of folds or flexures, where they may be difficult to detect with the forward-viewing colonoscope. The Third Eye Retroscope (TER) is a disposable device that is passed through the instrument channel of a standard colonoscope to provide a retrograde view that complements the forward view of the colonoscope during withdrawal.
Objective: To evaluate whether experience with the TER affects polyp detection rates and procedure times in experienced endoscopists who had not previously used the equipment.
Design, setting, patients: This was an open-label, prospective, multicenter study at 9 U.S. sites, involving 298 patients presenting for colonoscopy, evaluating the use of the TER in combination with a standard colonoscope.
Interventions: After cecal intubation, the TER was inserted through the instrument channel of the colonoscope. During withdrawal, the forward and retrograde video images were observed simultaneously on a wide-screen monitor.
Main outcome measurements: Primary outcome measures were the number and size of adenomas and all polyps detected with the standard colonoscope and with the colonoscope combined with the TER. Secondary outcome measures were withdrawal phase time and total procedure time. Each endoscopist examined 20 subjects, divided into quartiles according to the order of their procedures, and results were compared among quartiles.
Results: Overall, 182 polyps were detected with the colonoscope and 27 additional polyps with the TER, a 14.8% increase (P < .001). A total of 100 adenomas were detected with the colonoscope and 16 more with the TER, a 16.0% increase (P < .001). For procedures performed after each endoscopist had completed 15 procedures while using the TER, the mean additional detection rates with the TER were 17.0% for all polyps (P < .001) and 25.0% for adenomas (P < .001). For lesions 6 mm or larger, the overall additional detection rates with the TER for all polyps and for adenomas were 23.2% and 24.3%, respectively. For lesions 10 mm or larger, the overall additional detection rates with the TER for all polyps and for adenomas were 22.6% and 19.0%, respectively. The mean withdrawal times in the first and fourth quartiles were 10.6 and 9.2 minutes, respectively (P = .044).
Limitations: There was no randomization or separate control group. The endoscopists judged whether each lesion could have been detected with the colonscope alone by using their standard technique.
Conclusions: Polyp detection rates improved significantly with the TER, especially after 15 procedures, when the mean additional detection rate for adenomas was 25.0%. Additional detection rates with the TER for medium-size and large adenomas were greater than for smaller lesions. These results suggest that, compared with a colonoscope alone, a retrograde-viewing device can increase detection rates for clinically significant adenomas without detriment to procedure time or procedure complications. (
Clinical trial registration number: NCT00969124.).
2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Comment in
-
A retrograde-viewing device or a transparent hood for improving colorectal adenoma detection.Gastrointest Endosc. 2011 Mar;73(3):637; author reply 637-8. doi: 10.1016/j.gie.2010.06.046. Gastrointest Endosc. 2011. PMID: 21353861 No abstract available.
Similar articles
-
A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos).Gastrointest Endosc. 2010 Mar;71(3):551-6. doi: 10.1016/j.gie.2009.09.043. Epub 2009 Dec 16. Gastrointest Endosc. 2010. PMID: 20018280
-
Effect of a retrograde-viewing device on adenoma detection rate during colonoscopy: the TERRACE study.Gastrointest Endosc. 2011 Mar;73(3):480-9. doi: 10.1016/j.gie.2010.09.004. Epub 2010 Nov 10. Gastrointest Endosc. 2011. PMID: 21067735 Clinical Trial.
-
A novel retrograde-viewing auxiliary imaging device (Third Eye Retroscope) improves the detection of simulated polyps in anatomic models of the colon.Gastrointest Endosc. 2007 Jan;65(1):139-44. doi: 10.1016/j.gie.2006.07.044. Gastrointest Endosc. 2007. PMID: 17185094 Clinical Trial.
-
Emerging technological advancements in colonoscopy: Third Eye® Retroscope® and Third Eye® Panoramic(TM) , Fuse® Full Spectrum Endoscopy® colonoscopy platform, Extra-Wide-Angle-View colonoscope, and NaviAid(TM) G-EYE(TM) balloon colonoscope.Dig Endosc. 2015 Jan;27(2):223-31. doi: 10.1111/den.12382. Epub 2014 Nov 17. Dig Endosc. 2015. PMID: 25251748 Review.
-
Advanced technology for the improvement of adenoma and polyp detection during colonoscopy.Dig Endosc. 2015 Apr;27 Suppl 1:40-4. doi: 10.1111/den.12428. Dig Endosc. 2015. PMID: 25556542 Review.
Cited by
-
Colonoscopy for colorectal cancer screening.J Cancer. 2013;4(3):217-26. doi: 10.7150/jca.5829. Epub 2013 Mar 15. J Cancer. 2013. PMID: 23459594 Free PMC article.
-
Intraprocedural bowel cleansing with the JetPrep cleansing system improves adenoma detection.World J Gastroenterol. 2015 Jul 14;21(26):8184-94. doi: 10.3748/wjg.v21.i26.8184. World J Gastroenterol. 2015. PMID: 26185393 Free PMC article. Clinical Trial.
-
Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial.Lancet Oncol. 2014 Mar;15(3):353-60. doi: 10.1016/S1470-2045(14)70020-8. Epub 2014 Feb 20. Lancet Oncol. 2014. PMID: 24560453 Free PMC article. Clinical Trial.
-
Improving lesion detection during colonoscopy.Gastroenterol Hepatol (N Y). 2010 Oct;6(10):647-52. Gastroenterol Hepatol (N Y). 2010. PMID: 21103444 Free PMC article.
-
Endoscopic innovations to increase the adenoma detection rate during colonoscopy.World J Gastroenterol. 2014 Mar 7;20(9):2200-11. doi: 10.3748/wjg.v20.i9.2200. World J Gastroenterol. 2014. PMID: 24605019 Free PMC article. Review.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical