Comparative toxicity assessment of ozone and activated carbon treated sewage effluents using an in vivo test battery
- PMID: 20189626
- DOI: 10.1016/j.watres.2010.01.023
Comparative toxicity assessment of ozone and activated carbon treated sewage effluents using an in vivo test battery
Abstract
Wastewater treatment plants do not eliminate micropollutants completely and are thus important point sources for these substances. Ozonation and activated carbon treatment might be beneficial for ecosystem health as these techniques provide effective barriers to organic contaminants. However, a toxicity evaluation is required to investigate toxicity reduction and to assess the potential formation of toxic oxidation byproducts during ozonation. Therefore a comparative toxicity evaluation of different treated wastewater effluents was performed on site at a half scale treatment plant equipped with an ozonation step and an activated carbon treatment step in parallel subsequent to conventional activated sludge treatment. For this purpose four invertebrate and one higher plant toxicity test were selected to assess potential biological effects on whole organisms. The reproduction test with the mudsnail Potamopyrgus antipodarum exhibited a decreased reproductive output after advanced treatment compared to conventional treatment. This indicates an effective estrogenicity removal by ozonation and activated carbon treatment and is confirmed by results of the yeast estrogen screen with a reduction of in vitro estrogenic activity by >75%. The Lumbriculus variegatus test revealed a significantly enhanced toxicity after ozonation compared to conventional treatment whereas this effect was reduced following subsequent sand filtration. When ozonation was applied, a significantly increased genotoxicity was observed, detected with the comet assay using haemolymph of the zebra mussel. Again, this effect was removed by subsequent sand filtration to the level of conventional treatment. Activated carbon treatment even resulted in a significant reduction of genotoxicity. Adverse effects after the ozone reactor are possibly a result of the formation of toxic oxidation byproducts. Biologically active sand filtration obviously is an effective barrier to such compounds.
Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
JEM spotlight: Monitoring the treatment efficiency of a full scale ozonation on a sewage treatment plant with a mode-of-action based test battery.J Environ Monit. 2009 Oct;11(10):1836-46. doi: 10.1039/b907093a. Epub 2009 Jul 15. J Environ Monit. 2009. PMID: 19809706
-
Removal of micropollutants and reduction of biological activity in a full scale reclamation plant using ozonation and activated carbon filtration.Water Res. 2010 Jan;44(2):625-37. doi: 10.1016/j.watres.2009.09.048. Epub 2009 Oct 1. Water Res. 2010. PMID: 19863988
-
Whole effluent toxicity assessment at a wastewater treatment plant upgraded with a full-scale post-ozonation using aquatic key species.Chemosphere. 2012 Aug;88(8):1008-14. doi: 10.1016/j.chemosphere.2012.04.017. Epub 2012 May 3. Chemosphere. 2012. PMID: 22560180
-
Upflow anaerobic sludge blanket reactor--a review.Indian J Environ Health. 2001 Apr;43(2):1-82. Indian J Environ Health. 2001. PMID: 12397675 Review.
-
Safety and nutritional assessment of GM plants and derived food and feed: the role of animal feeding trials.Food Chem Toxicol. 2008 Mar;46 Suppl 1:S2-70. doi: 10.1016/j.fct.2008.02.008. Epub 2008 Feb 13. Food Chem Toxicol. 2008. PMID: 18328408 Review.
Cited by
-
Multi-taxon trends and the application of genotoxic biomarkers in the analysis of effluents from sewage treatment plant.Heliyon. 2023 Nov 21;9(12):e22516. doi: 10.1016/j.heliyon.2023.e22516. eCollection 2023 Dec. Heliyon. 2023. PMID: 38076150 Free PMC article. Review.
-
Do contaminants originating from state-of-the-art treated wastewater impact the ecological quality of surface waters?PLoS One. 2013 Apr 8;8(4):e60616. doi: 10.1371/journal.pone.0060616. Print 2013. PLoS One. 2013. PMID: 23593263 Free PMC article.
-
Impact of ozonation and biologically enhanced activated carbon filtration on the composition of micropollutants in drinking water.Environ Sci Pollut Res Int. 2019 Nov;26(33):33927-33935. doi: 10.1007/s11356-018-2700-0. Epub 2018 Jul 12. Environ Sci Pollut Res Int. 2019. PMID: 30003486
-
Post-ozonation in a municipal wastewater treatment plant improves water quality in the receiving stream.Environ Sci Eur. 2016;28(1):1. doi: 10.1186/s12302-015-0068-z. Epub 2016 Jan 5. Environ Sci Eur. 2016. PMID: 27752436 Free PMC article.
-
Reactions of N,O- and N,S-Azoles and -Azolines with Ozone: Kinetics and Mechanisms.Environ Sci Technol. 2025 Jul 15;59(27):14103-14115. doi: 10.1021/acs.est.5c01323. Epub 2025 Jun 27. Environ Sci Technol. 2025. PMID: 40577279 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources