The Entropy Module and Bispectral Index as guidance for propofol-remifentanil anaesthesia in combination with regional anaesthesia compared with a standard clinical practice group
- PMID: 20191792
- DOI: 10.1177/0310057X1003800125
The Entropy Module and Bispectral Index as guidance for propofol-remifentanil anaesthesia in combination with regional anaesthesia compared with a standard clinical practice group
Abstract
This study was designed to investigate the impact of the Entropy Module and Bispectral Index (BIS) monitoring on drug consumption and recovery times compared with standard anaesthetic practice in patients undergoing orthopaedic surgery using a combination of regional and general anaesthesia as performed by an experienced anaesthesiologist. We hypothesised that electroencephalogram monitoring would lead to a lower drug consumption as well as shorter recovery times. With institutional review board approval and written informed consent, 90 adult patients undergoing surgery to the upper or lower extremity received regional anaesthesia for post- and intraoperative pain control and were randomised to receive general anaesthesia by propofol/remifentanil infusion controlled either solely by clinical parameters or by targeting Entropy or BIS values of 50. Recovery times and drug consumption were recorded. Data from 79 patients were analysed. Compared with standard practice, patients with Entropy or BIS monitoring showed a similar propofol consumption (standard practice 101 +/- 22 microg/kg/minute, Entropy 106 +/- 24 microg/kg/minute, BIS 104 +/- 20 microg/kg/minute) and showed similar Aldrete scores (10/10) one minute after extubation: 9.1 +/- 0.3, 9.2 +/- 0.6 and 9.3 +/- 0.5, respectively. Time points of extubation were 7.3 +/- 2.9 minutes, 9.2 +/- 3.9 minutes and 6.8 +/- 2.9 minutes, respectively, demonstrating a significant difference between Entropy and BIS (P = 0.023). Compared with standard practice, targeting an Entropy or BIS value of 50 did not result in a reduction of propofol consumption during general anaesthesia combined with regional anaesthesia as performed by an experienced anaesthesiologist in orthopaedic patients.
Similar articles
-
Narcotrend monitoring allows faster emergence and a reduction of drug consumption in propofol-remifentanil anesthesia.Anesthesiology. 2003 Jul;99(1):34-41. doi: 10.1097/00000542-200307000-00009. Anesthesiology. 2003. PMID: 12826839 Clinical Trial.
-
Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: a multicentre study.Br J Anaesth. 2005 Jan;94(1):63-9. doi: 10.1093/bja/aei013. Epub 2004 Oct 29. Br J Anaesth. 2005. PMID: 15516347 Clinical Trial.
-
Surgical pleth index-guided remifentanil administration reduces remifentanil and propofol consumption and shortens recovery times in outpatient anaesthesia.Br J Anaesth. 2013 Apr;110(4):622-8. doi: 10.1093/bja/aes426. Epub 2012 Dec 5. Br J Anaesth. 2013. PMID: 23220856 Clinical Trial.
-
Use of cerebral monitoring during anaesthesia: effect on recovery profile.Best Pract Res Clin Anaesthesiol. 2006 Mar;20(1):181-9. doi: 10.1016/j.bpa.2005.08.001. Best Pract Res Clin Anaesthesiol. 2006. PMID: 16634424 Review.
-
Entropy.Best Pract Res Clin Anaesthesiol. 2006 Mar;20(1):101-9. doi: 10.1016/j.bpa.2005.07.009. Best Pract Res Clin Anaesthesiol. 2006. PMID: 16634417 Review.
Cited by
-
Bispectral index for improving intraoperative awareness and early postoperative recovery in adults.Cochrane Database Syst Rev. 2019 Sep 26;9(9):CD003843. doi: 10.1002/14651858.CD003843.pub4. Cochrane Database Syst Rev. 2019. PMID: 31557307 Free PMC article.
-
Spectral entropy monitoring for adults and children undergoing general anaesthesia.Cochrane Database Syst Rev. 2016 Mar 14;3(3):CD010135. doi: 10.1002/14651858.CD010135.pub2. Cochrane Database Syst Rev. 2016. PMID: 26976247 Free PMC article.
-
Bispectral index for improving anaesthetic delivery and postoperative recovery.Cochrane Database Syst Rev. 2014 Jun 17;2014(6):CD003843. doi: 10.1002/14651858.CD003843.pub3. Cochrane Database Syst Rev. 2014. Update in: Cochrane Database Syst Rev. 2019 Sep 26;9:CD003843. doi: 10.1002/14651858.CD003843.pub4. PMID: 24937564 Free PMC article. Updated.
-
EEG entropy measures in anesthesia.Front Comput Neurosci. 2015 Feb 18;9:16. doi: 10.3389/fncom.2015.00016. eCollection 2015. Front Comput Neurosci. 2015. PMID: 25741277 Free PMC article.
-
Use of Multiple EEG Features and Artificial Neural Network to Monitor the Depth of Anesthesia.Sensors (Basel). 2019 May 31;19(11):2499. doi: 10.3390/s19112499. Sensors (Basel). 2019. PMID: 31159263 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous