Accuracy and pitfalls of multidetector-row computed tomography in detecting spinal dural arteriovenous fistulas
- PMID: 20192621
- DOI: 10.3171/2009.9.SPINE0971
Accuracy and pitfalls of multidetector-row computed tomography in detecting spinal dural arteriovenous fistulas
Abstract
Object: The purpose of this study was to evaluate the accuracy of multidetector-row CT angiography (MDCTA) in demonstrating spinal dural arteriovenous fistulas (SDAVFs).
Methods: The authors studied 10 patients with SDAVFs, including 2 with spinal epidural AVFs, who underwent preoperative MR imaging, MDCTA, and digital subtraction angiography (DSA). In the evaluation of coronal sections of multiplanar reformation MDCTA images, inspection was focused on the presence of the following findings: 1) dilated perimedullary veins in the spinal canal; 2) focal enhancement of the nerve root, suggesting the location of the AVF, around the dural sleeve; and 3) a radicular vein that drains the AVF into perimedullary veins. The utility of MDCTA was assessed by comparing its findings with those of DSA in each case.
Results: Digital subtraction angiography confirmed that the AVFs were located in the thoracic spine in 4 patients and in the lumbar spine in 6 patients, and MDCTA detected dilated perimedullary veins in all 10 patients. In 8 patients, there was focal enhancement of the nerve root. The radicular vein that drains the AVF into the perimedullary veins was found in 8 cases. In 8 cases, the MDCTA-derived level and side of the AVF and its feeder corresponded with those shown by DSA. In 2 patients, however, the MDCTA-derived side of the feeder was on the side contralateral to the feeding artery confirmed by DSA. These lesions were interpreted as spinal epidural AVFs with perimedullary drainage. In 2 cases, MDCTA could not detect the multiplicity of their feeders.
Conclusions: The use of MDCTA preceding DSA can be helpful to focus the selective catheter angiography on certain spinal levels. However, one should keep in mind that epidural AVFs with perimedullary drainage may resemble SDAVFs and also that MDCTA cannot exclude the possibility of multiple feeders. Further research should elucidate how broadly selective angiography should explore around the MDCTA-suggested target.
Similar articles
-
Multi-detector-row CT angiography as a preoperative evaluation for spinal arteriovenous fistulae.Neurosurg Rev. 2007 Oct;30(4):321-6; discussion 327. doi: 10.1007/s10143-007-0088-2. Epub 2007 Jun 16. Neurosurg Rev. 2007. PMID: 17574485
-
[The Multi-detector-row CT angiography for diagnosis of spinal dural arteriovenous fistula].No Shinkei Geka. 2012 Aug;40(8):695-703. No Shinkei Geka. 2012. PMID: 22824575 Japanese.
-
Clinical utility of multidetector row computed tomography for diagnosing spinal dural arteriovenous fistulas undiagnosed by magnetic resonance imaging.Geriatr Gerontol Int. 2010 Jul;10(3):255-63. doi: 10.1111/j.1447-0594.2010.00618.x. Geriatr Gerontol Int. 2010. PMID: 20629759
-
Endovascular Management of Spinal Dural Arteriovenous Fistulas.J Neurol Surg A Cent Eur Neurosurg. 2016 Nov;77(6):523-526. doi: 10.1055/s-0035-1570002. Epub 2016 Jan 25. J Neurol Surg A Cent Eur Neurosurg. 2016. PMID: 26807619 Review.
-
Multiple spinal arteriovenous fistulas: A case-based review.Clin Neurol Neurosurg. 2015 Dec;139:6-11. doi: 10.1016/j.clineuro.2015.08.033. Epub 2015 Sep 2. Clin Neurol Neurosurg. 2015. PMID: 26355909 Review.
Cited by
-
Comparison of dynamic contrast-enhanced 3T MR and 64-row multidetector CT angiography for the localization of spinal dural arteriovenous fistulas.AJNR Am J Neuroradiol. 2014 Feb;35(2):407-12. doi: 10.3174/ajnr.A3660. Epub 2013 Aug 1. AJNR Am J Neuroradiol. 2014. PMID: 23907244 Free PMC article.
-
Application of 4D-CTA using 320-row area detector computed tomography on spinal arteriovenous fistulae: initial experience.Neurosurg Rev. 2013 Apr;36(2):289-96; discussion 296. doi: 10.1007/s10143-012-0440-z. Epub 2012 Nov 30. Neurosurg Rev. 2013. PMID: 23196422
-
Spinal dural arteriovenous fistulas: a review.Curr Atheroscler Rep. 2013 Jul;15(7):335. doi: 10.1007/s11883-013-0335-7. Curr Atheroscler Rep. 2013. PMID: 23666862 Review.
-
Surgical management of spinal dural arteriovenous fistulae: systematic review of current practices and open questions.Acta Neurochir (Wien). 2024 Nov 19;166(1):464. doi: 10.1007/s00701-024-06360-z. Acta Neurochir (Wien). 2024. PMID: 39560755
-
The accuracy and utility of contrast-enhanced MR angiography for localization of spinal dural arteriovenous fistulas: the Toronto experience.Eur Radiol. 2014 Nov;24(11):2885-94. doi: 10.1007/s00330-014-3307-6. Epub 2014 Jul 12. Eur Radiol. 2014. PMID: 25015136
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical