Speech breathing in speakers who use an electrolarynx
- PMID: 20193954
- DOI: 10.1016/j.jcomdis.2010.01.003
Speech breathing in speakers who use an electrolarynx
Abstract
Speakers who use an electrolarynx following a total laryngectomy no longer require pulmonary support for speech. Subsequently, chest wall movements may be affected; however, chest wall movements in these speakers are not well defined. The purpose of this investigation was to evaluate speech breathing in speakers who use an electrolarynx during speech and reading tasks. Six speakers who use an electrolarynx underwent an evaluation of chest wall kinematics (e.g., chest wall movements, temporal characteristics of chest wall movement), lung volumes, temporal measures of speech, and the interaction of linguistic influences on ventilation. Results of the present study were compared to previous reports in speakers who use an electrolarynx, as well as to previous reports in typical speakers. There were no significant differences in lung volumes used and the general movement of the chest wall by task; however, there were differences of note in the temporal aspects of chest wall configuration when compared to previous reports in both typical speakers and speakers who use an electrolarynx. These differences were related to timing and posturing of the chest wall. The lack of differences in lung volumes and chest wall movements by task indicates that neither reading nor spontaneous speech exerts a greater influence on speech breathing; however, the temporal and posturing results suggest the possibility of a decoupling of the respiratory system from speech following a total laryngectomy and subsequent alaryngeal speech rehabilitation.
Learning outcomes: The reader will be able to understand and describe: (1) The primary differences in speech breathing across alaryngeal speech options; (2) how speech breathing specifically differs (i.e., lung volumes and chest wall movements) in speakers who use an electrolarynx; (3) How the coupling of speech and respiration is altered when pulmonary air is no longer used for speech.
Copyright (c) 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Aerodynamic characteristics of laryngectomees breathing quietly and speaking with the electrolarynx.J Voice. 2004 Dec;18(4):567-77. doi: 10.1016/j.jvoice.2003.12.011. J Voice. 2004. PMID: 15567058
-
Chest wall kinematics during speech breathing in tracheoesophageal speakers.Ann Otol Rhinol Laryngol. 2012 Jan;121(1):28-37. doi: 10.1177/000348941212100106. Ann Otol Rhinol Laryngol. 2012. PMID: 22312925 Review.
-
The effects of a total laryngectomy on speech breathing.Curr Opin Otolaryngol Head Neck Surg. 2008 Jun;16(3):200-4. doi: 10.1097/MOO.0b013e3282fe96ac. Curr Opin Otolaryngol Head Neck Surg. 2008. PMID: 18475071 Review.
-
Speaking proficiency variations according to method of alaryngeal voicing.Laryngoscope. 1987 Jun;97(6):737-9. Laryngoscope. 1987. PMID: 3586817
-
Alaryngeal speech aid using an intra-oral electrolarynx and a miniature fingertip switch.Auris Nasus Larynx. 2005 Jun;32(2):157-62. doi: 10.1016/j.anl.2005.01.007. Epub 2005 Apr 9. Auris Nasus Larynx. 2005. PMID: 15917173
Cited by
-
The electrolarynx: voice restoration after total laryngectomy.Med Devices (Auckl). 2017 Jun 21;10:133-140. doi: 10.2147/MDER.S133225. eCollection 2017. Med Devices (Auckl). 2017. PMID: 28684925 Free PMC article. Review.
-
A hands-free wearable electrolarynx for communication in tracheostomized mechanically ventilated critically ill patients: a case series.J Anesth. 2025 Mar 12. doi: 10.1007/s00540-025-03481-2. Online ahead of print. J Anesth. 2025. PMID: 40072564
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources