Fast image reconstruction in fluorescence optical tomography using data compression
- PMID: 20195345
- DOI: 10.1364/OL.35.000763
Fast image reconstruction in fluorescence optical tomography using data compression
Abstract
We present a method for fast reconstruction in fluorescence optical tomography with very large data sets. In recent reports, CCD cameras at multiple positions have been used to collect optical measurements, producing more than 10(7) data samples. This makes storage of the full system Jacobian infeasible, and so data are usually subsampled. The method reported here allows use of the full data set, via image compression methods, and explicit construction of the (small) Jacobian, meaning optimal inversion methods can be applied, and thus leading to very fast reconstruction.
Similar articles
-
Hybrid Fourier-real space method for diffuse optical tomography.Opt Lett. 2010 Mar 1;35(5):688-90. doi: 10.1364/OL.35.000688. Opt Lett. 2010. PMID: 20195320
-
Surface Reconstruction for free-space 360 degrees fluorescence molecular tomography and the effects of animal motion.IEEE Trans Med Imaging. 2008 Feb;27(2):188-94. doi: 10.1109/TMI.2007.904662. IEEE Trans Med Imaging. 2008. PMID: 18334440
-
Fluorescence-enhanced three-dimensional lifetime imaging: a phantom study.Phys Med Biol. 2007 Jul 21;52(14):4155-70. doi: 10.1088/0031-9155/52/14/009. Epub 2007 Jun 15. Phys Med Biol. 2007. PMID: 17664600
-
Image analysis methods for diffuse optical tomography.J Biomed Opt. 2006 May-Jun;11(3):33001. doi: 10.1117/1.2209908. J Biomed Opt. 2006. PMID: 16822050 Review.
-
Towards Depth-Resolved Optical Imaging of Cardiac Electrical Activity.Adv Exp Med Biol. 2015;859:405-23. doi: 10.1007/978-3-319-17641-3_16. Adv Exp Med Biol. 2015. PMID: 26238062 Review.
Cited by
-
An adaptive Tikhonov regularization method for fluorescence molecular tomography.Med Biol Eng Comput. 2013 Aug;51(8):849-58. doi: 10.1007/s11517-013-1054-5. Epub 2013 Mar 16. Med Biol Eng Comput. 2013. PMID: 23504309
-
Split operator method for fluorescence diffuse optical tomography using anisotropic diffusion regularisation with prior anatomical information.Biomed Opt Express. 2011 Sep 1;2(9):2632-48. doi: 10.1364/BOE.2.002632. Epub 2011 Aug 19. Biomed Opt Express. 2011. PMID: 22091447 Free PMC article.
-
Fast 3D optical reconstruction in turbid media using spatially modulated light.Biomed Opt Express. 2010 Aug 3;1(2):471-481. doi: 10.1364/BOE.1.000471. Biomed Opt Express. 2010. PMID: 21258482 Free PMC article.
-
Accelerated image reconstruction in fluorescence molecular tomography using dimension reduction.Biomed Opt Express. 2013 Jan 1;4(1):1-14. doi: 10.1364/BOE.4.000001. Epub 2012 Dec 5. Biomed Opt Express. 2013. PMID: 23304643 Free PMC article.
-
Generalized mesh-based Monte Carlo for wide-field illumination and detection via mesh retessellation.Biomed Opt Express. 2015 Dec 18;7(1):171-84. doi: 10.1364/BOE.7.000171. eCollection 2016 Jan 1. Biomed Opt Express. 2015. PMID: 26819826 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources