Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2011 Mar;111(3):331-42.
doi: 10.1007/s00421-010-1396-8. Epub 2010 Feb 27.

Algorithms, modelling and VO₂ kinetics

Affiliations
Review

Algorithms, modelling and VO₂ kinetics

Carlo Capelli et al. Eur J Appl Physiol. 2011 Mar.

Erratum in

  • Eur J Appl Physiol. 2011 Mar;111(3):343. Carlo, Capelli [corrected to Capelli, Carlo]; Michela, Cautero [corrected to Cautero, Michela]; Silvia, Pogliaghi [corrected to Pogliaghi, Silvia]

Abstract

This article summarises the pros and cons of different algorithms developed for estimating breath-by-breath (B-by-B) alveolar O(2) transfer (VO 2A) in humans. VO 2A is the difference between O(2) uptake at the mouth and changes in alveolar O(2) stores (∆ VO(2s)), which for any given breath, are equal to the alveolar volume change at constant FAO2/FAiO2 ∆VAi plus the O(2) alveolar fraction change at constant volume [V Ai-1(F Ai - F Ai-1) O2, where V (Ai-1) is the alveolar volume at the beginning of a breath. Therefore, VO 2A can be determined B-by-B provided that V (Ai-1) is: (a) set equal to the subject's functional residual capacity (algorithm of Auchincloss, A) or to zero; (b) measured (optoelectronic plethysmography, OEP); (c) selected according to a procedure that minimises B-by-B variability (algorithm of Busso and Robbins, BR). Alternatively, the respiratory cycle can be redefined as the time between equal FO(2) in two subsequent breaths (algorithm of Grønlund, G), making any assumption of V (Ai-1) unnecessary. All the above methods allow an unbiased estimate of VO2 at steady state, albeit with different precision. Yet the algorithms "per se" affect the parameters describing the B-by-B kinetics during exercise transitions. Among these approaches, BR and G, by increasing the signal-to-noise ratio of the measurements, reduce the number of exercise repetitions necessary to study VO2 kinetics, compared to A approach. OEP and G (though technically challenging and conceptually still debated), thanks to their ability to track ∆VO(2s) changes during the early phase of exercise transitions, appear rather promising for investigating B-by-B gas exchange.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Physiol. 1989 Aug;415:459-75 - PubMed
    1. Eur J Appl Physiol. 2005 Dec;95(5-6):474-85 - PubMed
    1. Pflugers Arch. 2001 Jan;441(4):566-77 - PubMed
    1. Am J Physiol Regul Integr Comp Physiol. 2006 Apr;290(4):R1071-9 - PubMed
    1. Respir Physiol Neurobiol. 2008 Dec 31;164(3):291-9 - PubMed

Publication types

LinkOut - more resources