Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 May;21(5):1703-12.
doi: 10.1007/s10856-010-4030-8. Epub 2010 Feb 27.

Lens epithelial cell response to atmospheric pressure plasma modified poly(methylmethacrylate) surfaces

Affiliations

Lens epithelial cell response to atmospheric pressure plasma modified poly(methylmethacrylate) surfaces

Raechelle A D'Sa et al. J Mater Sci Mater Med. 2010 May.

Abstract

Selective control of cellular response to polymeric biomaterials is an important consideration for many ocular implant applications. In particular, there is often a need to have one surface of an ophthalmic implant capable of promoting cell attachment while the other needs to be resistant to this effect. In this study, an atmospheric pressure dielectric barrier discharge (DBD) has been used to modify the surface region of poly(methyl methacrylate) (PMMA), a well established ocular biomaterial, with the aim of promoting a controlled response to human lens epithelial cells (LEC) cultured thereon. The DBD plasma discharge environment has also been employed to chemically graft a layer of poly(ethylene glycol) methyl ether methacrylate (PEGMA) onto the PMMA and the response to LEC likewise determined. Two different molecular weights of PEGMA, namely 1000 and 2000 MW were used in these experiments. The LEC response to DBD treated polystyrene (PS) samples has also been examined as a positive control and to help to further elucidate the nature of the modified surfaces. The LEC adhered and proliferated readily on the DBD treated PMMA and PS surfaces when compared to the pristine polymer samples which showed little or no cell response. The PMMA and PS surfaces that had been DBD grafted with the PEGMA(1000) layer were found to have some adhered cells. However, on closer inspection, these cells were clearly on the verge of detaching. In the case of the PEGMA(2000) grafted surfaces no cells were observed indicating that the higher molecular weight PEGMA has been able to attain a surface conformation that is capable of resisting cell attachment in vitro.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Biomed Mater Res. 1997 Jul;36(1):99-108 - PubMed
    1. Surv Ophthalmol. 1997 Sep-Oct;42(2):175-89 - PubMed
    1. Dev Cell. 2004 Apr;6(4):483-95 - PubMed
    1. J Biol Chem. 2005 Mar 25;280(12):11626-34 - PubMed
    1. J Cataract Refract Surg. 1999 Jan;25(1):106-17 - PubMed

Publication types

LinkOut - more resources