Monte Carlo simulations of the dosimetry of chest tomosynthesis
Abstract
The aims of this work were to explore the dosimetry of chest tomosynthesis and to determine conversion factors between air kerma-area product (KAP) and the effective dose for different system configurations and patient sizes. Tomosynthesis systems were modelled with different angular intervals and tube voltages for the collection of the projection images as well as different distributions of the total exposure over the projections. The Monte Carlo-based computer software PCXMC developed by STUK (Radiation and Nuclear Safety Authority in Finland) was used to calculate the effective doses for each modelled tomosynthesis system for various patient sizes. The conversion factor between KAP and effective dose was obtained both for the zero-degree projection alone and for the entire tomosynthesis examination for each system configuration and patient size. The results reveal that the conversion factor for the zero-degree projection can be used to estimate the total effective dose from a tomosynthesis examination with acceptable accuracy, leading to an error smaller than 10 % irrespective of the system configuration and patient size. For higher accuracy, conversion factors between the total KAP and the total effective dose that take the angular interval and exposure configuration into account are presented for each system.
Similar articles
-
Effective dose to patients from chest examinations with tomosynthesis.Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):153-8. doi: 10.1093/rpd/ncq092. Epub 2010 Mar 16. Radiat Prot Dosimetry. 2010. PMID: 20233755
-
A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.Phys Med Biol. 2005 Sep 7;50(17):3989-4004. doi: 10.1088/0031-9155/50/17/005. Epub 2005 Aug 11. Phys Med Biol. 2005. PMID: 16177525
-
A Monte Carlo-based model for simulation of digital chest tomosynthesis.Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):159-63. doi: 10.1093/rpd/ncq079. Epub 2010 Mar 4. Radiat Prot Dosimetry. 2010. PMID: 20203125
-
X-ray tomosynthesis: a review of its use for breast and chest imaging.Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):100-7. doi: 10.1093/rpd/ncq099. Epub 2010 Mar 16. Radiat Prot Dosimetry. 2010. PMID: 20233756 Review.
-
A review of voxel model development and radiation protection applications at ENEA.Radiat Prot Dosimetry. 2010 Aug;140(4):383-90. doi: 10.1093/rpd/ncq124. Epub 2010 Apr 12. Radiat Prot Dosimetry. 2010. PMID: 20385543 Review.
Cited by
-
Dependency of image quality on acquisition protocol and image processing in chest tomosynthesis-a visual grading study based on clinical data.Br J Radiol. 2018 Jul;91(1087):20170683. doi: 10.1259/bjr.20170683. Epub 2018 Apr 9. Br J Radiol. 2018. PMID: 29565673 Free PMC article.
-
Virtual clinical trials in medical imaging: a review.J Med Imaging (Bellingham). 2020 Jul;7(4):042805. doi: 10.1117/1.JMI.7.4.042805. Epub 2020 Apr 11. J Med Imaging (Bellingham). 2020. PMID: 32313817 Free PMC article. Review.
-
Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes.Cancers (Basel). 2022 Feb 17;14(4):1027. doi: 10.3390/cancers14041027. Cancers (Basel). 2022. PMID: 35205775 Free PMC article.
-
Evaluation of a new system for chest tomosynthesis: aspects of image quality of different protocols determined using an anthropomorphic phantom.Br J Radiol. 2015 Sep;88(1053):20150057. doi: 10.1259/bjr.20150057. Epub 2015 Jun 29. Br J Radiol. 2015. PMID: 26118300 Free PMC article.
-
Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus.Med Phys. 2014 Feb;41(2):023901. doi: 10.1118/1.4859315. Med Phys. 2014. PMID: 24506654 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical