Real-time three-dimensional ultrasound with Live xPlane imaging assists first-trimester acquisition of a true midsagittal section
- PMID: 20201112
- DOI: 10.1002/uog.7613
Real-time three-dimensional ultrasound with Live xPlane imaging assists first-trimester acquisition of a true midsagittal section
Abstract
Objective: To determine whether real-time three-dimensional (3D) ultrasound with Live xPlane imaging, which enables the simultaneous display of two real-time high-quality image planes, can assist both operators certified by The Fetal Medicine Foundation (FMF) and non-FMF-certified operators in acquiring a true midsagittal plane in the first trimester.
Methods: Eight operators, four of them FMF certified (FMF group) and the other four not (non-FMF group), were asked to acquire a fetal image that they believed to represent the true midsagittal plane using real-time 3D ultrasound with Live xPlane imaging as guidance. Each operator was asked to obtain such an image five times from each of five patients. A total of 200 images from 40 patients were obtained and stored for subsequent analysis. All pregnancies were between 11 + 0 and 13 + 6 weeks of gestation. The angle between the falx cerebri and vertical axis (angle of deviation) was then measured by a single operator. A true midsagittal section was defined as an angle of deviation equal to 0 degrees. The angle of deviation and the time taken to acquire each image were compared between FMF and non-FMF groups.
Results: The median angle of deviation for each operator ranged from 1.2 degrees to 3.4 degrees. There was no significant difference in this angle between those who were FMF certified and those who were not (2.0 degrees vs. 2.2 degrees, P = 0.463). The interquartile range of the angle of deviation was also similar between the FMF- and non-FMF-certified operators. Although the time taken for image acquisition was longer among the non-FMF-certified operators (median, 45.5 s vs. 32.0 s), this difference did not reach statistical significance (P = 0.107).
Conclusion: Live xPlane imaging can provide a tool to assist the acquisition of a true midsagittal plane and to determine how true a 'midsagittal' plane really is.
Similar articles
-
How true is a 'true' midsagittal section?Ultrasound Obstet Gynecol. 2008 Dec;32(7):855-9. doi: 10.1002/uog.6125. Ultrasound Obstet Gynecol. 2008. PMID: 18973236
-
Use of three-dimensional (3D) sonography to assess the true midsagittal plane of fetal spine.J Matern Fetal Neonatal Med. 2011 Feb;24(2):297-300. doi: 10.3109/14767058.2010.487139. Epub 2010 May 26. J Matern Fetal Neonatal Med. 2011. PMID: 20504071
-
Learning curve in measurement of fetal frontomaxillary facial angle at 11-13 weeks of gestation.Ultrasound Obstet Gynecol. 2010 May;35(5):530-4. doi: 10.1002/uog.7574. Ultrasound Obstet Gynecol. 2010. PMID: 20127748
-
Three-dimensional ultrasound imaging and measurement of nasal bone length, prenasal thickness and frontomaxillary facial angle in normal second- and third-trimester fetuses.Ultrasound Obstet Gynecol. 2012 Jun;39(6):636-41. doi: 10.1002/uog.10058. Epub 2012 Apr 10. Ultrasound Obstet Gynecol. 2012. PMID: 21830246 Review.
-
Additional first-trimester ultrasound markers.Clin Lab Med. 2010 Sep;30(3):573-92. doi: 10.1016/j.cll.2010.04.004. Clin Lab Med. 2010. PMID: 20638573 Review.
Cited by
-
Concordance of tomographic ultrasound and multiplanar ultrasound in detecting levator ani muscle injury in patients with pelvic organ prolapse.PLoS One. 2018 Jul 6;13(7):e0199864. doi: 10.1371/journal.pone.0199864. eCollection 2018. PLoS One. 2018. PMID: 29979693 Free PMC article.
-
Visualization and quantitation of fetal movements by real-time three-dimensional ultrasound with live xPlane imaging in the first trimester of pregnancy.Croat Med J. 2016 Oct 31;57(5):474-481. doi: 10.3325/cmj.2016.57.474. Croat Med J. 2016. PMID: 27815938 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical