The zero-stress state of rat veins and vena cava
- PMID: 2020174
- DOI: 10.1115/1.2894083
The zero-stress state of rat veins and vena cava
Abstract
The zero-stress state of a vein is, like that of an artery, not a closed cylindrical tube, but is a series of segments whose cross-sections are open sectors. An opening angle of each sector is defined as the angle subtended between two radii joining the midpoint of the inner wall to the tips of the inner wall. Data on the opening angles (mean +/- standard deviation) of the veins and vena cava of the rat are presented. For the superior vena cava and subclavian, jugular, facial, renal, common iliac, saphenous, and plantar veins, the opening angle varies in the range of 25 to 75 deg. The inferior vena cava (below the heart), however, has noncircular, nonaxisymmetric cross-sections, a curved axis, and a rapid longitudinal variation of its "diameter"; its zero-stress state is not circular sectors; but the opening angle is still a useful characterization. The mean opening angle of the interior vena cava varies in the range of 40 to 150 deg in the thoracic portion, and 75 to 130 deg in the abdominal portion, with the larger values occurring about the middle of each portion. There are considerable length, diameter reductions, and wall thickening of the vena cava from the homeostatic state to the no-load state in vitro. Physically, the zero-stress state is the basis of the stress analysis of blood vessels. The change of opening angle is a convenient parameter to characterize any nonuniform remodeling of the vessel wall due to changes in physical stress or chemical environment.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Strain distribution in small blood vessels with zero-stress state taken into consideration.Am J Physiol. 1992 Feb;262(2 Pt 2):H544-52. doi: 10.1152/ajpheart.1992.262.2.H544. Am J Physiol. 1992. PMID: 1539714
-
Species dependence of the zero-stress state of aorta: pig versus rat.J Biomech Eng. 1991 Nov;113(4):446-51. doi: 10.1115/1.2895425. J Biomech Eng. 1991. PMID: 1762442
-
Duration of no-load state affects opening angle of porcine coronary arteries.Am J Physiol Heart Circ Physiol. 2006 May;290(5):H1871-8. doi: 10.1152/ajpheart.00910.2005. Epub 2005 Dec 9. Am J Physiol Heart Circ Physiol. 2006. PMID: 16339834
-
What are the residual stresses doing in our blood vessels?Ann Biomed Eng. 1991;19(3):237-49. doi: 10.1007/BF02584301. Ann Biomed Eng. 1991. PMID: 1928868 Review.
-
An experimental and clinical evaluation of grafts in the venous system.Surg Gynecol Obstet. 1970 Dec;131(6):1173-86. Surg Gynecol Obstet. 1970. PMID: 4920857 Review. No abstract available.
Cited by
-
Mapping motor neuron activity to overt behavior in the leech. I. Passive biomechanical properties of the body wall.J Comp Physiol A. 1996 May;178(5):637-54. doi: 10.1007/BF00227377. J Comp Physiol A. 1996. PMID: 8618216
-
Passive mechanical properties and constitutive modeling of blood vessels in relation to microstructure.Med Biol Eng Comput. 2008 Dec;46(12):1187-99. doi: 10.1007/s11517-008-0362-7. Epub 2008 Jul 9. Med Biol Eng Comput. 2008. PMID: 18612671
-
Residual deformations in ocular tissues.J R Soc Interface. 2015 Apr 6;12(105):20141101. doi: 10.1098/rsif.2014.1101. J R Soc Interface. 2015. PMID: 25740853 Free PMC article.
-
Matrix Metalloproteinase 9 (MMP-9) Regulates Vein Wall Biomechanics in Murine Thrombus Resolution.PLoS One. 2015 Sep 25;10(9):e0139145. doi: 10.1371/journal.pone.0139145. eCollection 2015. PLoS One. 2015. PMID: 26406902 Free PMC article.
-
Patient-specific artery shrinkage and 3D zero-stress state in multi-component 3D FSI models for carotid atherosclerotic plaques based on in vivo MRI data.Mol Cell Biomech. 2009 Jun;6(2):121-34. Mol Cell Biomech. 2009. PMID: 19444328 Free PMC article.