Source localization of ictal epileptic activity investigated by high resolution EEG and validated by SEEG
- PMID: 20206700
- DOI: 10.1016/j.neuroimage.2010.02.067
Source localization of ictal epileptic activity investigated by high resolution EEG and validated by SEEG
Abstract
High resolution electroencephalography (HR-EEG) combined with source localization methods has mainly been used to study interictal spikes and there have been few studies comparing source localization of scalp ictal patterns with depth EEG. To address this issue, 10 patients with four different scalp ictal patterns (ictal spikes, rhythmic activity, paroxysmal fast activity, obscured) were investigated by both HR-EEG and stereoelectroencephalography (SEEG). Sixty-four scalp-EEG sensors and a sampling rate of 1kHz were used to record scalp ictal patterns. Five different source models (moving dipole, rotating dipole, MUSIC, LORETA, and sLORETA) were used in order to perform source localization. Seven to 10 intracerebral electrodes were implanted during SEEG investigations. For each source model, the concordance between ictal source localization and epileptogenic zone defined by SEEG was assessed. Results were considered to agree if they localized in the same sublobar area as defined by a trained epileptologist. Across the study population, the best concordance between source localization methods and SEEG (9/10) was obtained with equivalent current dipole modeling. MUSIC and LORETA had a concordance of 7/10 whereas sLORETA had a concordance of only 5/10. Four of our patients classified into different groups (ictal spikes, paroxysmal fast activity, obscured) had complete concordance between source localization methods and SEEG. A high signal to noise ratio, a short time window of analysis (<1s) and bandpass filtering around the frequency of rhythmic activity allowed improvement of the source localization results. A high level of agreement between source localization methods and SEEG can be obtained for ictal spike patterns and for scalp-EEG paroxysmal fact activities whereas scalp rhythmic discharges can be accurately localized but originated from seizure propagation network.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Source localization of scalp-EEG interictal spikes in posterior cortex epilepsies investigated by HR-EEG and SEEG.Epilepsia. 2009 Feb;50(2):276-89. doi: 10.1111/j.1528-1167.2008.01742.x. Epub 2008 Aug 19. Epilepsia. 2009. PMID: 18717708
-
The impact of cerebral source area and synchrony on recording scalp electroencephalography ictal patterns.Epilepsia. 2007 Nov;48(11):2167-76. doi: 10.1111/j.1528-1167.2007.01224.x. Epub 2007 Jul 28. Epilepsia. 2007. PMID: 17662060
-
Spatiotemporal source analysis in scalp EEG vs. intracerebral EEG and SPECT: a case study in a 2-year-old child.Neurophysiol Clin. 2012 Jun;42(4):207-24. doi: 10.1016/j.neucli.2011.11.001. Epub 2011 Dec 2. Neurophysiol Clin. 2012. PMID: 22632869
-
EEG source localization of the epileptogenic focus in patients with refractory temporal lobe epilepsy, dipole modelling revisited.Acta Neurol Belg. 2007 Sep;107(3):71-7. Acta Neurol Belg. 2007. PMID: 18072334 Review.
-
Cortical substrates of scalp EEG epileptiform discharges.J Clin Neurophysiol. 2007 Apr;24(2):96-100. doi: 10.1097/WNP.0b013e31803ecdaf. J Clin Neurophysiol. 2007. PMID: 17414965 Review.
Cited by
-
Brain Source Imaging in Preclinical Rat Models of Focal Epilepsy using High-Resolution EEG Recordings.J Vis Exp. 2015 Jun 6;(100):e52700. doi: 10.3791/52700. J Vis Exp. 2015. PMID: 26131755 Free PMC article.
-
Localisation of epileptic foci using novel imaging modalities.Curr Opin Neurol. 2013 Aug;26(4):368-73. doi: 10.1097/WCO.0b013e328363372c. Curr Opin Neurol. 2013. PMID: 23823464 Free PMC article. Review.
-
EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy.Brain Commun. 2021 Nov 19;3(4):fcab278. doi: 10.1093/braincomms/fcab278. eCollection 2021. Brain Commun. 2021. PMID: 34877536 Free PMC article.
-
EEG source connectivity to localize the seizure onset zone in patients with drug resistant epilepsy.Neuroimage Clin. 2017 Sep 14;16:689-698. doi: 10.1016/j.nicl.2017.09.011. eCollection 2017. Neuroimage Clin. 2017. PMID: 29034162 Free PMC article.
-
Extracting the Invisible: Mesial Temporal Source Detection in Simultaneous EEG and SEEG Recordings.Brain Topogr. 2023 Mar;36(2):192-209. doi: 10.1007/s10548-023-00940-5. Epub 2023 Feb 2. Brain Topogr. 2023. PMID: 36732440
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical