Variation of interstitial glucose measurements assessed by continuous glucose monitors in healthy, nondiabetic individuals
- PMID: 20215454
- PMCID: PMC2875442
- DOI: 10.2337/dc09-1971
Variation of interstitial glucose measurements assessed by continuous glucose monitors in healthy, nondiabetic individuals
Abstract
Objective: To characterize glucose levels during daily living using continuous glucose monitors (CGMs) in nondiabetic individuals.
Research design and methods: Seventy-four healthy children, adolescents, and adults aged 9-65 years with normal glucose tolerance used a blinded CGM device for 3 to 7 days.
Results: Sensor glucose concentrations were 71-120 mg/dl for 91% of the day. Sensor values were <or=60 or >140 mg/dl for only 0.2% and 0.4% of the day, respectively. Sensor glucose concentrations were slightly higher in children than adults (P = 0.009) and were slightly lower during the night than day (95 vs. 99 mg/dl, P < 0.001).
Conclusions: Glucose values <or=60 and >140 mg/dl, measured with CGM, are uncommon in healthy, nondiabetic individuals. CGM may be useful to evaluate glucose tolerance in nondiabetic individuals over time. Furthermore, these data provide a basis for comparison for studies that use CGM to assess glucose control in subjects with diabetes.
Similar articles
-
Continuous Glucose Monitoring Profiles in Healthy Nondiabetic Participants: A Multicenter Prospective Study.J Clin Endocrinol Metab. 2019 Oct 1;104(10):4356-4364. doi: 10.1210/jc.2018-02763. J Clin Endocrinol Metab. 2019. PMID: 31127824 Free PMC article.
-
Diabetes technology and treatments in the paediatric age group.Int J Clin Pract Suppl. 2011 Feb;(170):76-82. doi: 10.1111/j.1742-1241.2010.02582.x. Int J Clin Pract Suppl. 2011. PMID: 21323816 Review.
-
Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes.Exp Clin Endocrinol Diabetes. 2006 Feb;114(2):63-7. doi: 10.1055/s-2006-923887. Exp Clin Endocrinol Diabetes. 2006. PMID: 16570235 Clinical Trial.
-
Accuracy assessment of online glucose monitoring by a subcutaneous enzymatic glucose sensor during exercise in patients with type 1 diabetes treated by continuous subcutaneous insulin infusion.Diabetes Metab. 2013 May;39(3):258-62. doi: 10.1016/j.diabet.2012.12.004. Epub 2013 Mar 19. Diabetes Metab. 2013. PMID: 23522730
-
The Use of Continuous Glucose Monitors in Sport: Possible Applications and Considerations.Int J Sport Nutr Exerc Metab. 2022 Dec 26;33(2):121-132. doi: 10.1123/ijsnem.2022-0139. Print 2023 Mar 1. Int J Sport Nutr Exerc Metab. 2022. PMID: 36572039 Review.
Cited by
-
Glycemic Profiles of Healthy Individuals with Low Fasting Plasma Glucose and HbA1c.ISRN Endocrinol. 2011;2011:435047. doi: 10.5402/2011/435047. Epub 2011 Dec 8. ISRN Endocrinol. 2011. PMID: 22363877 Free PMC article.
-
Continuous Glucose Monitoring in Healthy Adults-Possible Applications in Health Care, Wellness, and Sports.Sensors (Basel). 2022 Mar 5;22(5):2030. doi: 10.3390/s22052030. Sensors (Basel). 2022. PMID: 35271177 Free PMC article. Review.
-
Hypoglycemic symptoms in the absence of diabetes: Pilot evidence of clinical hypoglycemia in young women.J Clin Transl Endocrinol. 2019 Jul 24;18:100202. doi: 10.1016/j.jcte.2019.100202. eCollection 2019 Dec. J Clin Transl Endocrinol. 2019. PMID: 31428564 Free PMC article.
-
Precision Medicine: Long-Term Treatment with Sulfonylureas in Patients with Neonatal Diabetes Due to KCNJ11 Mutations.Curr Diab Rep. 2019 Jun 27;19(8):52. doi: 10.1007/s11892-019-1175-9. Curr Diab Rep. 2019. PMID: 31250216 Free PMC article. Review.
-
Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes.J Diabetes Sci Technol. 2022 Mar;16(2):373-382. doi: 10.1177/1932296820965599. Epub 2020 Oct 26. J Diabetes Sci Technol. 2022. PMID: 33100059 Free PMC article.