Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study
- PMID: 20215664
- DOI: 10.4103/0970-4388.60478
Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study
Abstract
Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde) and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.
Similar articles
-
The sterilization of endodontic hand files.J Endod. 1996 Jun;22(6):321-2. doi: 10.1016/S0099-2399(96)80268-8. J Endod. 1996. PMID: 8934994
-
An evaluation of sterilization of endodontic instruments in artificial sponges.J Endod. 1998 Jan;24(1):51-3. doi: 10.1016/S0099-2399(98)80215-X. J Endod. 1998. PMID: 9487869
-
[The effectiveness of glass bead sterilizer in the dental practice].Refuat Hapeh Vehashinayim (1993). 2008 Apr;25(2):36-9, 75. Refuat Hapeh Vehashinayim (1993). 2008. PMID: 18780544 Hebrew.
-
Sterilization of endoscopic instruments.Curr Opin Urol. 2014 Mar;24(2):195-202. doi: 10.1097/MOU.0000000000000034. Curr Opin Urol. 2014. PMID: 24451088 Review.
-
Sterilization. Disciplined microbial control.Dent Clin North Am. 1991 Apr;35(2):339-55. Dent Clin North Am. 1991. PMID: 2032579 Review.
Cited by
-
Electrophysiological features of cortical 3D networks are deeply modulated by scaffold properties.APL Bioeng. 2024 Aug 22;8(3):036112. doi: 10.1063/5.0214745. eCollection 2024 Sep. APL Bioeng. 2024. PMID: 39193551 Free PMC article.
-
Efficacy of Different Techniques for Removing Debris from Endodontic Files Prior to Sterilization.J Int Oral Health. 2015 Aug;7(8):42-6. J Int Oral Health. 2015. PMID: 26464538 Free PMC article.
-
A Comparative In-Vitro Study of the Effectiveness of Several Methods of Sterilizing Endodontic Files.Cureus. 2024 Nov 26;16(11):e74473. doi: 10.7759/cureus.74473. eCollection 2024 Nov. Cureus. 2024. PMID: 39726458 Free PMC article.
-
Effectiveness of the Glass Bead Sterilizer for Sterilizing Surgical Instruments.J Am Assoc Lab Anim Sci. 2022 May 1;61(3):252-255. doi: 10.30802/AALAS-JAALAS-21-000053. Epub 2022 Mar 21. J Am Assoc Lab Anim Sci. 2022. PMID: 35314021 Free PMC article.
-
A comparison of decontamination methods of tried-in preformed metal crowns: an in-vivo study.Eur Arch Paediatr Dent. 2019 Dec;20(6):537-544. doi: 10.1007/s40368-018-00414-4. Epub 2019 Mar 25. Eur Arch Paediatr Dent. 2019. PMID: 30906953
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources