Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Oct;38(4):400-6.
doi: 10.1016/j.ejcts.2010.01.060. Epub 2010 Mar 12.

Aortic root and cusp configuration determine aortic valve function

Affiliations

Aortic root and cusp configuration determine aortic valve function

Benjamin Oliver Bierbach et al. Eur J Cardiothorac Surg. 2010 Oct.

Abstract

Objective: Normalisation of aortic root and cusp configuration is a prerequisite for successful aortic valve repair (AVR). Using transthoracic echocardiography, we studied aortic root dimensions relative to body size in normal subjects and AVR patients.

Methods: Aortic roots of healthy volunteers (n=130, age 27.9 ± 16.9 years) were examined for aortoventricular (AV), sinus (S), sinutubular-junction diameters (ST) and effective height (height difference between the AV plane and central coaptation point, eH) by transthoracic echocardiography. In 651 patients, after AVR residual aortic valve insufficiency (AI) and eH were determined. The relationships between eH versus root dimensions and eH versus residual AI were analysed by analysis of variance with Bonferroni post hoc testing.

Results: Root dimensions correlated with each other and body size (r=0.74-0.91). In addition, a correlation between AV (r=0.73), sinus diameter (r=0.76), body height (r=0.77), body surface area (r=0.81) and eH was found. After AVR, eH was 9.8 ± 0.9 mm in 235 patients without postoperative AI, 9.4 ± 1.1mm in 370 with mild AI, 7.9 ± 1.4mm in 43 patients with moderate AI and 6 ± 1mm in three patients with severe AI. The difference in means of effective height between the groups was significant (p<0.005). Of 497 AVR patients with an eH ≥ 9 mm, 309 had no or trivial AI, 186 had mild AI and only two had moderate AI.

Conclusions: Parameters of aortic root dimensions follow a seemingly constant pattern in humans of different sizes. Effective height has a constant relationship to root dimensions and body size. In AVR, normalisation of eH leads to a high probability of normal or near-normal aortic valve function.

PubMed Disclaimer

MeSH terms

LinkOut - more resources