Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Jun;38(6):480-9.
doi: 10.1016/j.jdent.2010.03.002. Epub 2010 Mar 9.

An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques

Affiliations
Randomized Controlled Trial

An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques

A Banerjee et al. J Dent. 2010 Jun.

Abstract

Objectives: To assess amounts of residual dentine retained after using three excavation techniques; the microtensile bond strengths (microTBS) to residual dentine, comparing etch-rinse vs. self-etching adhesives.

Methods: 42 carious molars were subdivided (N=21) dependent upon adhesive/composite system (Adper Scotchbond 1XT and Filtek Supreme vs. Filtek Silorane adhesive and composite). Dividing into three (N=7), dependent upon caries excavation technique employed (hand vs. chemo-mechanical: Carisolv gel vs. experimental enzymatic gel (SFC-V)), caries removal was assessed using visual/tactile criteria and in situ autofluorescence (AF) confocal fibre-optic micro-endoscopy (CFOME). Post-restoration/four-week hydrated storage, four 0.9 mm(2) beams per tooth underwent microTBS testing/microscopic analysis of fractured surfaces. Three cavities from each excavation group were analysed using SEM.

Results: SEM revealed surface roughness with smear layer occluding tubule orifices in hand-excavated samples and a reduced, variable smear layer for both chemo-mechanical systems. CFOME AF assessment indicated hand excavation left sound dentine, Carisolv left affected dentine and SFC-V slightly under-prepared clinically. Mean microTBS values from etch-rinse samples (27 MPa (SD 3.9), hand; 22 MPa (SD 5.1), Carisolv; 26 MPa (SD 4.4), SFC-V) showed statistical differences between hand and Carisolv groups. Mean microTBS data for self-etch samples (22 MPa (SD 3.3), hand; 27 MPa (SD 6.1), Carisolv; 25 MPa (SD 4.7), SFC-V) showed significant differences between hand and Carisolv, and hand vs. SFC-V. Failure loci distribution in etch-rinse samples was between dentine-adhesive, within adhesive and within composite whereas self-etch samples exhibited failure predominantly between adhesive and composite.

Conclusions: Data indicated that all null hypotheses were disproved.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources