Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients
- PMID: 20223628
- DOI: 10.1016/j.jvs.2009.12.041
Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients
Abstract
Background: Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population.
Methods: Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months.
Results: As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths.
Conclusions: Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively implemented algorithm, thereby limiting the need for transport in this high-risk population.
Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Similar articles
-
Technical factors affecting the accuracy of bedside IVC filter placement using intravascular ultrasound.Vasc Endovascular Surg. 2012 May;46(4):293-9. doi: 10.1177/1538574411434495. Epub 2012 Apr 27. Vasc Endovascular Surg. 2012. PMID: 22544870
-
Bedside inferior vena cava filter placement by intravascular ultrasound in critically ill patients is safe and effective for an extended time.J Vasc Surg Venous Lymphat Disord. 2014 Oct;2(4):377-82. doi: 10.1016/j.jvsv.2014.04.007. Epub 2014 Jun 2. J Vasc Surg Venous Lymphat Disord. 2014. PMID: 26993541
-
Bedside vena cava filter placement guided with intravascular ultrasound.J Vasc Surg. 2001 Jul;34(1):21-6. doi: 10.1067/mva.2001.115599. J Vasc Surg. 2001. PMID: 11436070
-
Bedside placement of inferior vena cava filters by using transabdominal duplex ultrasonography and intravascular ultrasound imaging.J Vasc Surg. 2005 Nov;42(5):1027-32. doi: 10.1016/j.jvs.2005.06.027. J Vasc Surg. 2005. PMID: 16275468 Review.
-
Intravascular ultrasound-guided bedside placement of inferior vena cava filters.Semin Vasc Surg. 2006 Sep;19(3):150-4. doi: 10.1053/j.semvascsurg.2006.06.002. Semin Vasc Surg. 2006. PMID: 16996417 Review.
Cited by
-
Feasibility study of hand-carried ultrasound-guided retrievable inferior vena cava filter placement.Ann Transl Med. 2021 Apr;9(8):689. doi: 10.21037/atm-21-1290. Ann Transl Med. 2021. PMID: 33987387 Free PMC article.
-
Inferior Vena Cava Filter in Cancer-Associated Thrombosis: A Vade Mecum for the Treating Physicians: A Narrative Review.Biomedicines. 2024 Sep 30;12(10):2230. doi: 10.3390/biomedicines12102230. Biomedicines. 2024. PMID: 39457543 Free PMC article. Review.
-
The role of intravascular ultrasound in venous thromboembolism.Semin Intervent Radiol. 2012 Mar;29(1):10-5. doi: 10.1055/s-0032-1302446. Semin Intervent Radiol. 2012. PMID: 23450229 Free PMC article.
-
Comparative outcomes of Inferior Vena Cava filters placed at bedside using digital radiography versus conventional fluoroscopy.J Interv Med. 2021 May 12;4(3):139-142. doi: 10.1016/j.jimed.2021.05.001. eCollection 2021 Aug. J Interv Med. 2021. PMID: 34805962 Free PMC article.
-
Digital radiograph (DR) guided bedside IVC filter placements in patients with intracranial pressure monitors.J Interv Med. 2021 Aug 19;4(4):208-211. doi: 10.1016/j.jimed.2021.08.005. eCollection 2021 Nov. J Interv Med. 2021. PMID: 35586379 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous