Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units: a multi-institutional randomized controlled trial
- PMID: 20224364
- DOI: 10.1097/SLA.0b013e3181d48a6a
Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units: a multi-institutional randomized controlled trial
Abstract
Objective: To investigate whether maximal sterile barrier precautions (MSBPs) during central venous catheter (CVC) insertion are truly effective in preventing catheter-related bloodstream infections (CRBSIs) in patients in general surgical units.
Summary background data: The reported effectiveness of MSBPs was based on the results of a single-center randomized controlled trial by Raad et al and the majority of the patients (99%) in the study were chemotherapy outpatients.
Methods: Between March 14, 2004 and December 28, 2006, the patients scheduled for CVC insertion in surgical units at 9 medical centers in Japan were randomly assigned to either an MSBP group (n = 211) or a standard sterile barrier precaution (SSBP) group (n = 213). This study was registered in the UMIN Clinical Trials Registry (registration ID number: UMIN000001400).
Results: The median (range) duration of catheterization was 14 days (0-92 days) in the MSBP group and 14 days (0-112 days) in the SSBP group. There were 5 cases (2.4%) of CRBSI in the MSBP group and 6 cases (2.8%) in the SSBP group (relative risk, 0.84; 95% confidence interval, 0.26-2.7; P = 0.77). The rate of CRBSIs per 1000 catheter days was 1.5 in the MSBP group and 1.6 in the SSBP group. There were 8 cases (3.8%) of catheter-related infections in the MSBP group and 7 cases (3.3%) in the SSBP group (relative risk, 1.2; 95% confidence interval, 0.43-3.1; P = 0.78). The rate of catheter-related infection per 1000 catheter days was 2.4 in the MSBP group and 1.9 in the SSBP group.
Conclusions: This study is larger in sample size than the one performed by Raad et al and could not demonstrate better prevention of CRBSIs by MSBP compared with SSBP. A large randomized controlled trial or at least a meta-analysis of any other studies in the literature is necessary to reach to a conclusion on this issue.
Comment in
-
No reason to conclude that maximal sterile barrier precautions do not reduce catheter-related blood stream infections.Ann Surg. 2011 Jan;253(1):212-3. doi: 10.1097/SLA.0b013e318205107a. Ann Surg. 2011. PMID: 21135688 No abstract available.
-
Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units.Ann Surg. 2011 Jun;253(6):1234-5; author reply 1235. doi: 10.1097/sla.0b013e31821c7eb8. Ann Surg. 2011. PMID: 21739642 No abstract available.
Similar articles
-
No reason to conclude that maximal sterile barrier precautions do not reduce catheter-related blood stream infections.Ann Surg. 2011 Jan;253(1):212-3. doi: 10.1097/SLA.0b013e318205107a. Ann Surg. 2011. PMID: 21135688 No abstract available.
-
Prevention of central venous catheter bloodstream infections.J Intensive Care Med. 2010 May-Jun;25(3):131-8. doi: 10.1177/0885066609358952. Epub 2010 Jan 19. J Intensive Care Med. 2010. PMID: 20089527 Review.
-
Central line-associated bloodstream infections: prevention and management.Infect Dis Clin North Am. 2011 Mar;25(1):77-102. doi: 10.1016/j.idc.2010.11.012. Infect Dis Clin North Am. 2011. PMID: 21315995 Review.
-
Central venous catheter-related bloodstream infections: improving post-insertion catheter care.J Hosp Infect. 2009 Feb;71(2):117-22. doi: 10.1016/j.jhin.2008.09.016. Epub 2008 Nov 14. J Hosp Infect. 2009. PMID: 19013680
-
Preventing catheter-related bloodstream infections: an executive summary of the APIC elimination guide.Am J Infect Control. 2010 Dec;38(10):846-8. doi: 10.1016/j.ajic.2010.08.008. Epub 2010 Oct 25. Am J Infect Control. 2010. PMID: 20971529
Cited by
-
Skin antisepsis for reducing central venous catheter-related infections.Cochrane Database Syst Rev. 2016 Jul 13;7(7):CD010140. doi: 10.1002/14651858.CD010140.pub2. Cochrane Database Syst Rev. 2016. PMID: 27410189 Free PMC article.
-
New materials and devices for preventing catheter-related infections.Ann Intensive Care. 2011 Aug 18;1:34. doi: 10.1186/2110-5820-1-34. Ann Intensive Care. 2011. PMID: 21906266 Free PMC article.
-
Venue of catheter insertion does not significantly impact the event of central line-associated bloodstream infection in patients with haematological diseases.Infect Prev Pract. 2020 Mar 4;2(2):100050. doi: 10.1016/j.infpip.2020.100050. eCollection 2020 Jun. Infect Prev Pract. 2020. PMID: 34368700 Free PMC article.
-
Prevention of Device-Related Healthcare-Associated Infections.F1000Res. 2016 Jan 14;5:F1000 Faculty Rev-65. doi: 10.12688/f1000research.7493.1. eCollection 2016. F1000Res. 2016. PMID: 26918162 Free PMC article. Review.
-
Randomized controlled trials in central vascular access devices: A scoping review.PLoS One. 2017 Mar 21;12(3):e0174164. doi: 10.1371/journal.pone.0174164. eCollection 2017. PLoS One. 2017. PMID: 28323880 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous