Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units: a multi-institutional randomized controlled trial
- PMID: 20224364
- DOI: 10.1097/SLA.0b013e3181d48a6a
Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units: a multi-institutional randomized controlled trial
Abstract
Objective: To investigate whether maximal sterile barrier precautions (MSBPs) during central venous catheter (CVC) insertion are truly effective in preventing catheter-related bloodstream infections (CRBSIs) in patients in general surgical units.
Summary background data: The reported effectiveness of MSBPs was based on the results of a single-center randomized controlled trial by Raad et al and the majority of the patients (99%) in the study were chemotherapy outpatients.
Methods: Between March 14, 2004 and December 28, 2006, the patients scheduled for CVC insertion in surgical units at 9 medical centers in Japan were randomly assigned to either an MSBP group (n = 211) or a standard sterile barrier precaution (SSBP) group (n = 213). This study was registered in the UMIN Clinical Trials Registry (registration ID number: UMIN000001400).
Results: The median (range) duration of catheterization was 14 days (0-92 days) in the MSBP group and 14 days (0-112 days) in the SSBP group. There were 5 cases (2.4%) of CRBSI in the MSBP group and 6 cases (2.8%) in the SSBP group (relative risk, 0.84; 95% confidence interval, 0.26-2.7; P = 0.77). The rate of CRBSIs per 1000 catheter days was 1.5 in the MSBP group and 1.6 in the SSBP group. There were 8 cases (3.8%) of catheter-related infections in the MSBP group and 7 cases (3.3%) in the SSBP group (relative risk, 1.2; 95% confidence interval, 0.43-3.1; P = 0.78). The rate of catheter-related infection per 1000 catheter days was 2.4 in the MSBP group and 1.9 in the SSBP group.
Conclusions: This study is larger in sample size than the one performed by Raad et al and could not demonstrate better prevention of CRBSIs by MSBP compared with SSBP. A large randomized controlled trial or at least a meta-analysis of any other studies in the literature is necessary to reach to a conclusion on this issue.
Comment in
-
No reason to conclude that maximal sterile barrier precautions do not reduce catheter-related blood stream infections.Ann Surg. 2011 Jan;253(1):212-3. doi: 10.1097/SLA.0b013e318205107a. Ann Surg. 2011. PMID: 21135688 No abstract available.
-
Maximal sterile barrier precautions do not reduce catheter-related bloodstream infections in general surgery units.Ann Surg. 2011 Jun;253(6):1234-5; author reply 1235. doi: 10.1097/sla.0b013e31821c7eb8. Ann Surg. 2011. PMID: 21739642 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous