A new applicator, positionable to the center of tracheobronchial lumen for HDR-IR-192-afterloading of tracheobronchial tumors
- PMID: 2022506
- DOI: 10.1016/0360-3016(91)90205-i
A new applicator, positionable to the center of tracheobronchial lumen for HDR-IR-192-afterloading of tracheobronchial tumors
Abstract
A new bronchial applicator for afterloading irradiation is introduced which can be positioned to the center of the tracheobronchial lumen. The central position in the lumen leads to a clear improvement of dose distribution. The applicator is built on the principle of a coaxial tube. Parts of the outer cover can be expanded to baskets and effect a distance of the radiation source from the bronchial mucosa or tumor surface, and at the same time, expend a relief of extreme contact doses. No obstruction of the respiratory system through the positioning device will be caused. The positionable bronchial applicator seems to be suitable for reducing complications caused through high contact doses and irregular dose distributions and may be able to improve the results of endoluminal radiotherapy.
Similar articles
-
[Endobronchial intraluminal brachytherapy for patients with tracheobronchial carcinoma with high dose-rate 192-Iridium remote afterloading method].Nihon Igaku Hoshasen Gakkai Zasshi. 1992 Jun 25;52(6):841-3. Nihon Igaku Hoshasen Gakkai Zasshi. 1992. PMID: 1641316 Japanese.
-
[Endoluminal irradiation of tracheobronchial tumors using a high dose rate iridium-192 afterloading device].Strahlenther Onkol. 1988 Apr;164(4):202-7. Strahlenther Onkol. 1988. PMID: 2834832 German.
-
[Endobronchial brachytherapy with high dose rate 192Ir afterloading technique using a new applicator].Nihon Igaku Hoshasen Gakkai Zasshi. 1996 Jan;56(1):42-7. Nihon Igaku Hoshasen Gakkai Zasshi. 1996. PMID: 8857098 Clinical Trial. Japanese.
-
[Brachytherapy in the treatment of lung and tracheal cancer: current indications, methods, results].Przegl Lek. 2006;63(8):664-73. Przegl Lek. 2006. PMID: 17441380 Review. Polish.
-
The role of brachytherapy in the treatment and control of central bronchial carcinoma.Monaldi Arch Chest Dis. 1996 Aug;51(4):325-8. Monaldi Arch Chest Dis. 1996. PMID: 8909019 Review.
Cited by
-
Applicator for light delivery and in situ light dosimetry during endobronchial photodynamic therapy: First measurements in humans.Lasers Med Sci. 1997 Oct;12(3):253-9. doi: 10.1007/BF02765106. Lasers Med Sci. 1997. PMID: 20803333
-
[Malignant tracheal tumors--surgical experiences in 6 patients with primary malignancies of the trachea. Current diagnosis and therapy].Langenbecks Arch Chir. 1996;381(1):23-33. doi: 10.1007/BF00184251. Langenbecks Arch Chir. 1996. PMID: 8717171 German.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical