Comparative Study
. 2010 Apr;66(4):349-55.
doi: 10.1016/j.diagmicrobio.2009.11.010.

Triplex real-time polymerase chain reaction assay for simultaneous detection of Staphylococcus aureus and coagulase-negative staphylococci and determination of methicillin resistance directly from positive blood culture bottles

Affiliations
Comparative Study

Triplex real-time polymerase chain reaction assay for simultaneous detection of Staphylococcus aureus and coagulase-negative staphylococci and determination of methicillin resistance directly from positive blood culture bottles

Abdullah Kilic et al. Diagn Microbiol Infect Dis. 2010 Apr.

Abstract

We describe here a 1-step, triplex real-time polymerase chain reaction (PCR) assay for the detection and identification of staphylococci directly from signal-positive blood culture bottles containing Gram-positive cocci in clusters (GPCC). The triplex assay targeted and detected tuf, nuc, and mecA genes in a single tube and had a detection limit of 10(5) CFU/mL for each gene target. A total of 341 GPCC-positive blood culture bottles were collected between November 12, 2008, and August 11, 2009. Among them, 230 methicillin-resistant coagulase-negative staphylococci (CoNS), 54 methicillin-susceptible CoNS, 22 methicillin-resistant Staphylococcus aureus, 22 methicillin-susceptible S. aureus, and 13 nonstaphylococci species were identified by conventional methods. The results obtained by triplex assay were in agreement with those of conventional methods for tuf (99.7%), nuc (100.0%), and mecA (99.1%), respectively. The triplex assay was found to have sensitivities of 99.7%, 100%, and 99.2% and specificities of 100%, 100%, and 98.7%, respectively, for the tuf, nuc, and mecA gene targets. The triplex real-time PCR assay accurately detects and identifies staphylococci directly from positive blood cultures without nucleic acid extraction prior to amplification.