. 2010 May;7(5):280-9.
doi: 10.1080/15459621003680227.

Metalworking fluid-related aerosols in machining plants

Affiliations

Metalworking fluid-related aerosols in machining plants

Yan Gilbert et al. J Occup Environ Hyg. 2010 May.

Abstract

Respiratory problems are observed in machinists using soluble metalworking fluid (MWF). Evidences suggest that these problems could be related to the aerosolized microorganisms and their byproducts from MWF. To establish MWF aerosol exposure thresholds and to better understand their effect on human health, these aerosols must be fully characterized. This article evaluates airborne microorganisms and aerosols from soluble MWF in the working environment. Air quality parameters (endotoxin levels, culturable airborne microorganisms, fluid mist, inhalable dust and air exchange rates) were evaluated at 44 sites, in 25 shops in Quebec, Canada. Microorganism concentrations were also measured in MWF. Culturable airborne bacteria concentrations were low, ranging from 1.2 x 10(1) to 1.5 x 10(3) CFU (colony forming units) m(-3), even for metalworking fluid highly contaminated by bacteria (up to 2.4 x 10(9) CFU mL(-1)). Inhalable dust varied between < 0.1 to 2.6 mg m(-3), while air exchange rates were mostly below the standard (4 h(-1)) for this type of workplace, between 0.6 to 14.2 h(-1). Only nine of 44 sites respected the suggested minimum value for air exchange rates. Fluid mist ranged from 0.02 to 0.89 mg m(-3), which is below the threshold limit value (TLV) (ACGIH) of 5 mg m(-3). Airborne endotoxin concentrations ranged from undetectable to 183 EU m(-3) (endotoxin units), showing no correlation with airborne microorganisms or inhalable dust. Most workstations respected the suggested minimum values for fluid mist and showed low concentrations of airborne endotoxin, culturable microorganisms and inhalable dust despite fluid contamination, even when air exchange rates were below the recommendations. Airborne Pseudomonas pseudoalcaligenes was recovered from many sites at significant concentrations. Health-associated risks following exposure to this microorganism should be further investigated.

PubMed Disclaimer

Publication types

LinkOut - more resources