Comparison of QIAGEN automated nucleic acid extraction methods for CMV quantitative PCR testing
- PMID: 20231608
- DOI: 10.1309/AJCPE5VZL1ONZHFJ
Comparison of QIAGEN automated nucleic acid extraction methods for CMV quantitative PCR testing
Abstract
We examined the effect of nucleic acid extraction methods on the analytic characteristics of a quantitative polymerase chain reaction (PCR) assay for cytomegalovirus (CMV). Human serum samples were extracted with 2 automated instruments (BioRobot EZ1 and QIAsymphony SP, QIAGEN, Valencia, CA) and CMV PCR results compared with those of pp65 antigenemia testing. Both extraction methods yielded results that were comparably linear and precise, whereas the QIAsymphony SP had a slightly lower limit of detection (1.92 log(10) copies/mL vs 2.26 log(10) copies/mL). In both cases, PCR was more sensitive than CMV antigen detection, detecting CMV viremia in 12% (EZ1) and 21% (QIAsymphony) of antigen-negative specimens. This study demonstrates the feasibility of using 2 different extraction techniques to yield results within 0.5 log(10) copies/mL of the mean value, a level that would allow for clinical comparison between different laboratory assays.
Similar articles
-
Quantitation of cytomegalovirus DNA by real-time polymerase chain reaction in peripheral blood specimens of patients with solid organ transplants: comparison with end-point PCR and pp65 antigen test.J Med Virol. 2006 Jul;78(7):915-22. doi: 10.1002/jmv.20641. J Med Virol. 2006. PMID: 16721848
-
Comparison of quantitative competitive polymerase chain reaction-enzyme-linked immunosorbent assay with LightCycler-based polymerase chain reaction for measuring cytomegalovirus DNA in patients after hematopoietic stem cell transplantation.Diagn Microbiol Infect Dis. 2006 Feb;54(2):115-20. doi: 10.1016/j.diagmicrobio.2005.08.021. Epub 2006 Jan 9. Diagn Microbiol Infect Dis. 2006. PMID: 16406183
-
Relationship of cytomegalovirus load assessed by real-time PCR to pp65 antigenemia in organ transplant recipients.J Clin Virol. 2008 Aug;42(4):335-42. doi: 10.1016/j.jcv.2008.03.031. Epub 2008 May 21. J Clin Virol. 2008. PMID: 18495527
-
Quantitative analysis in molecular diagnostics.Hum Pathol. 1994 Jun;25(6):572-9. doi: 10.1016/0046-8177(94)90221-6. Hum Pathol. 1994. PMID: 8013946 Review.
-
Quality control for nucleic acid tests: common ground and special issues.J Clin Virol. 2001 Jan;20(1-2):15-21. doi: 10.1016/s1386-6532(00)00150-5. J Clin Virol. 2001. PMID: 11163578 Review.
Cited by
-
Torque teno virus viremia load size in patients with selected congenital defects of innate immunity.Clin Vaccine Immunol. 2011 Apr;18(4):692-4. doi: 10.1128/CVI.00466-10. Epub 2011 Feb 16. Clin Vaccine Immunol. 2011. PMID: 21325487 Free PMC article.
-
Automated Nucleic Acid Extraction Systems for Detecting Cytomegalovirus and Epstein-Barr Virus Using Real-Time PCR: A Comparison Study Between the QIAsymphony RGQ and QIAcube Systems.Ann Lab Med. 2017 Mar;37(2):129-136. doi: 10.3343/alm.2017.37.2.129. Ann Lab Med. 2017. PMID: 28028999 Free PMC article.
-
Increasing Cytomegalovirus Detection Rate from Respiratory Tract Specimens by a New Laboratory-Developed Automated Molecular Diagnostic Test.Microorganisms. 2020 Jul 16;8(7):1063. doi: 10.3390/microorganisms8071063. Microorganisms. 2020. PMID: 32708818 Free PMC article.
-
Comparative evaluation of three automated systems for DNA extraction in conjunction with three commercially available real-time PCR assays for quantitation of plasma Cytomegalovirus DNAemia in allogeneic stem cell transplant recipients.J Clin Microbiol. 2011 Aug;49(8):2899-904. doi: 10.1128/JCM.00785-11. Epub 2011 Jun 22. J Clin Microbiol. 2011. PMID: 21697323 Free PMC article.
-
Automated high throughput DNA isolation for detection of human papillomavirus in oral rinse samples.J Clin Virol. 2011 Apr;50(4):270-5. doi: 10.1016/j.jcv.2010.12.005. Epub 2011 Jan 26. J Clin Virol. 2011. PMID: 21273118 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources