. 2010 May;36(5):888-96.
doi: 10.1007/s00134-010-1849-x. Epub 2010 Mar 16.

The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume

Affiliations

The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume

D G Tingay et al. Intensive Care Med. 2010 May.

Abstract

Purpose: To examine the impact of different endotracheal tube (ETT) suction techniques on regional end-expiratory lung volume (EELV) and tidal volume (V(T)) in an animal model of surfactant-deficient lung injury.

Methods: Six 2-week old piglets were intubated (4.0 mm ETT), muscle-relaxed and ventilated, and lung injury was induced with repeated saline lavage. In each animal, open suction (OS) and two methods of closed suction (CS) were performed in random order using both 5 and 8 French gauge (FG) catheters. The pre-suction volume state of the lung was standardised on the inflation limb of the pressure-volume relationship. Regional EELV and V(T) expressed as a proportion of the impedance change at vital capacity (%Z (VCroi)) within the anterior and posterior halves of the chest were measured during and for 60 s after suction using electrical impedance tomography.

Results: During suction, 5 FG CS resulted in preservation of EELV in the anterior (non-dependent) and posterior (dependent) lung compared to the other permutations, but these only reached significance in the anterior regions (p < 0.001 repeated-measures ANOVA). V(T) within the anterior, but not posterior lung was significantly greater during 5FG CS compared to 8 FG CS; the mean difference was 15.1 [95% CI 5.1, 25.1]%Z (VCroi). Neither catheter size nor suction technique influenced post-suction regional EELV or V(T) compared to pre-suction values (repeated-measures ANOVA).

Conclusions: ETT suction causes transient loss of EELV and V(T) throughout the lung. Catheter size exerts a greater influence than suction method, with CS only protecting against derecruitment when a small catheter is used, especially in the non-dependent lung.

PubMed Disclaimer

Comment in

  • Suction catheter tip as an endobronchial foreign body.
    Blohm ME, Vezyroglou K, Riedel F, Roth B, Singer D. Blohm ME, et al. Intensive Care Med. 2011 Dec;37(12):2052-3. doi: 10.1007/s00134-011-2363-5. Epub 2011 Sep 27. Intensive Care Med. 2011. PMID: 21946928 No abstract available.

Similar articles

Cited by

References

    1. Intensive Care Med. 2007 Sep;33(9):1655-62 - PubMed
    1. Am J Respir Crit Care Med. 2004 Nov 15;170(10):1066-72 - PubMed
    1. Intensive Care Med. 1992;18(6):319-21 - PubMed
    1. Anesthesiology. 2006 Jan;104(1):39-47 - PubMed
    1. Pediatr Pulmonol. 1992 Jun;13(2):121-3 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources