. 2010 Apr-May;139(1-3):153-8.
doi: 10.1093/rpd/ncq092. Epub 2010 Mar 16.

Effective dose to patients from chest examinations with tomosynthesis

Affiliations

Effective dose to patients from chest examinations with tomosynthesis

Magnus Båth et al. Radiat Prot Dosimetry. 2010 Apr-May.

Abstract

Chest tomosynthesis, which refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest, is an imaging technique recently introduced to health care. The main purpose of the present work was to determine the average effective dose to patients from clinical use of chest tomosynthesis. Exposure data for two chest radiography laboratories with tomosynthesis option (Definium 8000 with VolumeRAD option, GE Healthcare, Chalfont St. Giles, UK) were registered for 20 patients with a weight between 60 and 80 kg (average weight of 70.2 kg). The recorded data were used in the Monte Carlo program PCXMC 2.0 (STUK-Radiation and Nuclear Safety Authority, Helsinki, Finland) to determine the average effective dose for each projection. The effective dose for the chest tomosynthesis examination, including a scout view and the tomosynthesis acquisition, was finally obtained by adding the effective doses from all projections. Using the weighting factors given in ICRP 103, the average effective dose for the examination was found to be 0.13 mSv, whereas the average effective dose for the conventional two-view chest radiography examination was 0.05 mSv. A conversion factor of 0.26 mSv Gy(-1) cm(-2) was found suitable for determining the effective dose from a VolumeRAD chest tomosynthesis examination from the total registered kerma-area product. In conclusion, the effective dose to a standard-sized patient (170 cm/70 kg) from a VolumeRAD chest tomosynthesis examination is ~2 % of an average chest CT and only two to three times the effective dose from the conventional two-view chest radiography examination.

PubMed Disclaimer

Similar articles

Cited by

Publication types