Bismuth coating of non-tunneled haemodialysis catheters reduces bacterial colonization: a randomized controlled trial
- PMID: 20237055
- PMCID: PMC2905443
- DOI: 10.1093/ndt/gfq052
Bismuth coating of non-tunneled haemodialysis catheters reduces bacterial colonization: a randomized controlled trial
Abstract
Background: Haemodialysis (HD) catheter-related blood stream infections are a major cause of morbidity and mortality in patients with acute and chronic renal failure.
Methods: We conducted a randomized, prospective, double-blinded trial investigating the clinical value of bismuth-coated non-tunneled HD catheters in patients in need of temporary short-term vascular access. A standard catheter (SC) was compared to a surface-modified, bismuth-film-coated catheter (FCC). After removal of the catheter for any reason, both arterial and venous lumina were rinsed and the fluid cultured for detection of bacterial colony-forming units (CFU). The catheter tip was placed in a tube containing sterile saline, sonicated and shortly centrifuged to remove debris (3 min at 1000 g). The supernatant was cultured and assayed for DNA content.
Results: Seventy-seven patients in three HD units were randomized. Thirteen patients suffered from acute renal failure, 60 patients from chronic renal failure, and four patients without renal insufficiency were treated with plasma exchange. The time to catheter removal was not significantly different between groups, with a mean of 18.5 +/- 2 days for SC and 15.1 +/- 2 days for FCC. In most cases, the reasons for catheter removal were related to no further need for extracorporeal therapy or establishment of a permanent vascular access. Six catheters for SC and four catheters for FCC were removed because of presumed infection. Bacterial colonization was significantly lower for coated catheters compared to standard catheters, both for cultured catheter tips as well as for CFU in rinse fluids (P < 0.05).
Conclusions: Surface modification with bismuth film reduces bacterial colonization of temporary non-tunneled HD catheters in a clinical trial. Larger trials with these modified catheters are justified to further investigate the effect on catheter-related infections, complications and costs.
Figures





Similar articles
-
Tunneled hemodialysis catheters: use of a silver-coated catheter for prevention of infection--a randomized study.Radiology. 1998 May;207(2):491-6. doi: 10.1148/radiology.207.2.9577500. Radiology. 1998. PMID: 9577500 Clinical Trial.
-
Frequency of catheter related infections in haemodialysed uraemic patients.J Pak Med Assoc. 2010 Aug;60(8):671-5. J Pak Med Assoc. 2010. PMID: 20726202
-
Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients: a multicenter, randomized, controlled study.Crit Care Med. 2012 Feb;40(2):420-9. doi: 10.1097/CCM.0b013e31822f0d4b. Crit Care Med. 2012. PMID: 21926583 Clinical Trial.
-
Prevention and management of hemodialysis catheter infections.Expert Rev Anti Infect Ther. 2012 Dec;10(12):1447-55. doi: 10.1586/eri.12.134. Expert Rev Anti Infect Ther. 2012. PMID: 23253322 Review.
-
A systematic review and meta-analysis of the comparison of performance among step-tip, split-tip, and symmetrical-tip hemodialysis catheters.J Vasc Surg. 2019 Apr;69(4):1282-1292. doi: 10.1016/j.jvs.2018.09.029. J Vasc Surg. 2019. PMID: 30905366
Cited by
-
Exometabolome analysis identifies pyruvate dehydrogenase as a target for the antibiotic triphenylbismuthdichloride in multiresistant bacterial pathogens.J Biol Chem. 2012 Jan 20;287(4):2887-95. doi: 10.1074/jbc.M111.288894. Epub 2011 Dec 5. J Biol Chem. 2012. PMID: 22144679 Free PMC article.
-
Clinical and Regulatory Considerations for Central Venous Catheters for Hemodialysis.Clin J Am Soc Nephrol. 2018 Dec 7;13(12):1924-1932. doi: 10.2215/CJN.14251217. Epub 2018 Oct 11. Clin J Am Soc Nephrol. 2018. PMID: 30309840 Free PMC article.
-
SiO2 nanosphere coated tough catheter with superhydrophobic surface for improving the antibacteria and hemocompatibility.Front Bioeng Biotechnol. 2023 Jan 10;10:1067139. doi: 10.3389/fbioe.2022.1067139. eCollection 2022. Front Bioeng Biotechnol. 2023. PMID: 36704310 Free PMC article.
-
Temporary hemodialysis catheters: recent advances.Kidney Int. 2014 Nov;86(5):888-95. doi: 10.1038/ki.2014.162. Epub 2014 May 7. Kidney Int. 2014. PMID: 24805107 Free PMC article. Review.
-
Prevention of central line-associated bloodstream infections: a journey toward eliminating preventable harm.Curr Infect Dis Rep. 2011 Aug;13(4):343-9. doi: 10.1007/s11908-011-0186-8. Curr Infect Dis Rep. 2011. PMID: 21556693
References
-
- Foley RN, Chen SC, Collins AJ. Hemodialysis access at initiation in the United States, 2005 to 2007: still “catheter first”. Hemodial Int. 2009;13:533–542. - PubMed
-
- Allon M, Daugirdas J, Depner TA, et al. Effect of change in vascular access on patient mortality in hemodialysis patients. Am J Kidney Dis. 2006;47:469–477. - PubMed
-
- Mokrzycki MH, Zhang M, Cohen H, et al. Tunnelled haemodialysis catheter bacteraemia: risk factors for bacteraemia recurrence, infectious complications and mortality. Nephrol Dial Transplant. 2006;21:1024–1031. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical