Dynamic analysis of iris configuration with anterior segment optical coherence tomography
- PMID: 20237248
- DOI: 10.1167/iovs.09-3941
Dynamic analysis of iris configuration with anterior segment optical coherence tomography
Abstract
Purpose: To evaluate dynamic changes in iris configuration and their association with anterior chamber angle width by using anterior segment optical coherence tomography (ASOCT).
Methods: Forty-six normal subjects with open angles and 40 with narrow angles (Shaffer grade < or =2 in three or more quadrants during dark room gonioscopy) were analyzed. The dynamic ASOCT dark-light changes of iris bowing were captured with real-time video recording and nasal iris bowing, nasal anterior chamber angle, and pupil diameter were measured in serial image frames selected from the video capture. The associations between iris bowing, iris thickness, anterior chamber depth (ACD), age, anterior chamber angle, and pupillary diameter measurements were evaluated with univariate and multivariate regression analyses.
Results: The relationship between iris bowing and pupil diameter was largely linear, with three dynamic patterns observed: (1) convex-to-convex (iris remains convex in dark and light); (2) concave-to-convex (iris changes from concave to convex from light to dark); and (3) concave-to-concave (iris remains concave in dark and light). All the subjects with narrow angles had convex-to-convex anatomy, although 43% of the subjects with open angles also demonstrated this pattern. These individuals were older and had shorter axial length (both with P < 0.001). Older age (r = -0.352, P = 0.001), smaller ACD (r = 0.382, P < 0.001), and smaller difference in angle opening distance in light and dark (r = 0.472, P < 0.001) were associated with smaller differences in iris bowing in the light and dark. ACD and iris bowing were independently associated with anterior chamber angle width.
Conclusions: Independent of ACD, iris bowing is an important biometric parameter that determines angle width. Investigation of iris dynamics may offer a new perspective in understanding the risk and mechanism of primary angle closure.
Similar articles
-
Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT.Invest Ophthalmol Vis Sci. 2007 Sep;48(9):4116-22. doi: 10.1167/iovs.07-0010. Invest Ophthalmol Vis Sci. 2007. PMID: 17724195
-
Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.Ophthalmology. 2007 Jan;114(1):33-9. doi: 10.1016/j.ophtha.2006.05.073. Epub 2006 Oct 27. Ophthalmology. 2007. PMID: 17070597
-
Quantitative iris parameters and association with narrow angles.Ophthalmology. 2010 Jan;117(1):11-7. doi: 10.1016/j.ophtha.2009.06.017. Epub 2009 Oct 7. Ophthalmology. 2010. PMID: 19815290
-
Optical coherence tomography imaging of the anterior chamber angle.Ophthalmol Clin North Am. 2005 Sep;18(3):375-81, vi. doi: 10.1016/j.ohc.2005.05.007. Ophthalmol Clin North Am. 2005. PMID: 16054995 Review.
-
Anterior chamber angle assessment techniques.Surv Ophthalmol. 2008 May-Jun;53(3):250-73. doi: 10.1016/j.survophthal.2007.10.012. Surv Ophthalmol. 2008. PMID: 18501270 Review.
Cited by
-
Clinical applications of anterior segment optical coherence tomography.J Ophthalmol. 2015;2015:605729. doi: 10.1155/2015/605729. Epub 2015 Mar 3. J Ophthalmol. 2015. PMID: 25821589 Free PMC article. Review.
-
Ethnic difference of the anterior chamber area and volume and its association with angle width.Invest Ophthalmol Vis Sci. 2012 May 31;53(6):3139-44. doi: 10.1167/iovs.12-9776. Invest Ophthalmol Vis Sci. 2012. PMID: 22531702 Free PMC article.
-
Contribution of different anatomical and physiologic factors to iris contour and anterior chamber angle changes during pupil dilation: theoretical analysis.Invest Ophthalmol Vis Sci. 2013 Apr 26;54(4):2977-84. doi: 10.1167/iovs.12-10748. Invest Ophthalmol Vis Sci. 2013. PMID: 23482467 Free PMC article.
-
Anterior chamber angle imaging with swept-source optical coherence tomography: comparison between CASIAII and ANTERION.Sci Rep. 2020 Oct 30;10(1):18771. doi: 10.1038/s41598-020-74813-3. Sci Rep. 2020. PMID: 33127944 Free PMC article.
-
Association between baseline angle width and induced angle opening following prophylactic laser peripheral iridotomy.Invest Ophthalmol Vis Sci. 2013 May 1;54(5):3763-70. doi: 10.1167/iovs.13-11597. Invest Ophthalmol Vis Sci. 2013. PMID: 23661374 Free PMC article. Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources