Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Aug;51(8):4067-74.
doi: 10.1167/iovs.09-4301. Epub 2010 Mar 17.

Adjusted peripapillary retinal nerve fiber layer thickness measurements based on the optic nerve head scan angle

Affiliations
Free article

Adjusted peripapillary retinal nerve fiber layer thickness measurements based on the optic nerve head scan angle

Samin Hong et al. Invest Ophthalmol Vis Sci. 2010 Aug.
Free article

Abstract

Purpose: To verify the effect of the scan angle of the optic nerve head (ONH) on measurements of peripapillary retinal nerve fiber layer (RNFL) thickness by using spectral-domain optical coherence tomography (OCT).

Methods: Both eyes of 64 healthy volunteers were scanned by the optic disc cube 200 x 200 scan of a spectral-domain OCT system. Ultra-high resolution OCT images of the ONH were used to determine the horizontal, vertical, and three-dimensional scan angles of the ONH. The adjusted clock-hour RNFL thicknesses generated by the three-dimensional scan angle of the ONH were then compared with the original clock-hour RNFL thicknesses.

Results: The mean horizontal, vertical, and three-dimensional scan angles of the ONH were 12.62 +/- 5.17 degrees, 4.17 +/- 3.30 degrees, and 13.62 +/- 5.13 degrees, respectively. In 125 (97.66%) eyes, the scanned ONH image was tilted temporally; in 89 (69.53%) eyes it was tilted inferiorly. The adjusted clock-hour RNFL thicknesses generated by the three-dimensional scan angle of the ONH were significantly different from the original values (P = 0.009); the mean difference was 13.26 +/- 14.95 microm, and the overall correlation and agreement were not excellent, especially in the inferior quadrant.

Conclusions: Current intraretinal imaging devices such as OCT assume that the ONH is positioned exactly in front of the scanning beam; however, this assumption appears to be inaccurate. Because the scan angle of the ONH varies and also influences RNFL thickness measurements, it may be better to consider using the ONH scan angle as an adjustment factor when peripapillary RNFL thicknesses are calculated by OCT.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources