Reliability of visual field results over repeated testing
- PMID: 2023736
- DOI: 10.1016/s0161-6420(91)32339-x
Reliability of visual field results over repeated testing
Abstract
Fifty-one normal subjects, 337 with ocular hypertension, and 55 patients with glaucoma underwent C-30-2 testing on the Humphrey Field Analyzer on at least three occasions over a 6-year period. The time between tests was approximately 1 year. Using the manufacturer's standard for a reliable field (false-positive and false-negative rates, less than 33%; fixation losses, less than 20%), no trends in the proportion of reliable fields or the component indices were observed over time. Four percent of normal subjects, 9% of those with ocular hypertension, and 8% of patients with glaucoma were unable to meet the reliability standard every time they were tested. This repeated lack of reliability was due almost exclusively to fixation losses. However, patients with glaucoma were more likely to have repeatedly high false-negative responses than those with ocular hypertension or normal subjects, providing further evidence that false-negative responses are more indicative of glaucoma than of patient reliability.
Similar articles
-
Reliability of computerized perimetric threshold tests as assessed by reliability indices and threshold reproducibility in patients with suspect and manifest glaucoma.Acta Ophthalmol Scand. 2000 Oct;78(5):519-22. doi: 10.1034/j.1600-0420.2000.078005519.x. Acta Ophthalmol Scand. 2000. PMID: 11037906
-
A prospective three-year study of response properties of normal subjects and patients during automated perimetry.Ophthalmology. 1993 Feb;100(2):269-74. doi: 10.1016/s0161-6420(93)31660-x. Ophthalmology. 1993. PMID: 8437837
-
Screening for glaucomatous visual field loss. The effect of patient reliability.Ophthalmology. 1990 Aug;97(8):1032-7. doi: 10.1016/s0161-6420(90)32467-3. Ophthalmology. 1990. PMID: 2402414
-
Role of visual field reliability indices in ruling out glaucoma.JAMA Ophthalmol. 2015 Jan;133(1):40-4. doi: 10.1001/jamaophthalmol.2014.3609. JAMA Ophthalmol. 2015. PMID: 25256758
-
Compass fundus automated perimetry.Eur J Ophthalmol. 2018 Sep;28(5):481-490. doi: 10.1177/1120672118757667. Epub 2018 Mar 22. Eur J Ophthalmol. 2018. PMID: 29564933 Review.
Cited by
-
Detection of glaucoma in a cohort of chinese subjects with systemic hypertension.J Ophthalmol. 2013;2013:463710. doi: 10.1155/2013/463710. Epub 2013 Jan 14. J Ophthalmol. 2013. PMID: 23401742 Free PMC article.
-
Effect of a patient training video on visual field test reliability.Br J Ophthalmol. 2003 Feb;87(2):153-6. doi: 10.1136/bjo.87.2.153. Br J Ophthalmol. 2003. PMID: 12543740 Free PMC article. Clinical Trial.
-
Prospective Assessment of Early Proton Therapy-Induced Optic Neuropathy in Patients With Intracranial, Orbital or Sinonasal Tumors: Impact of A Standardized Ophthalmological Follow Up.Front Oncol. 2021 Jun 15;11:673886. doi: 10.3389/fonc.2021.673886. eCollection 2021. Front Oncol. 2021. PMID: 34211847 Free PMC article.
-
Reliability of Binocular Esterman Visual Field Test in Patients with Glaucoma and Other Ocular Conditions.Diagnostics (Basel). 2024 Feb 16;14(4):433. doi: 10.3390/diagnostics14040433. Diagnostics (Basel). 2024. PMID: 38396473 Free PMC article.
-
Spatial correlation between localized decreases in exploratory visual search performance and areas of glaucomatous visual field loss.Graefes Arch Clin Exp Ophthalmol. 2019 Jan;257(1):153-160. doi: 10.1007/s00417-018-4164-9. Epub 2018 Oct 27. Graefes Arch Clin Exp Ophthalmol. 2019. PMID: 30368564
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources