A semiclosed-loop algorithm for the control of blood glucose levels in diabetics
- PMID: 2026432
- DOI: 10.1109/10.68209
A semiclosed-loop algorithm for the control of blood glucose levels in diabetics
Abstract
In this paper, a theoretical analysis of the control of plasma glucose levels in diabetic individuals is undertaken using a simple mathematical model of the dynamics of glucose and insulin interaction in the blood system. Mathematical optimization techniques are applied to the mathematical model to derive insulin infusion programs for the control of blood levels in diabetic individuals. Based on the results of the mathematical optimization, a semiclosed-loop algorithm is proposed for continuous insulin delivery to diabetic patients. The algorithm is based on three hourly plasma glucose samples. A theoretical evaluation of the effectiveness of this algorithm shows that it is superior to two existing algorithms in controlling hyperglycemia. A glucose infusion term representing the effect of glucose intake resulting from a meal is then introduced into the model equations. Various insulin infusion programs for the control of plasma glucose levels following a meal are then assessed. The theoretical results suggest that the most effective short-term control is achieved by an insulin infusion program which incorporates an injection to coincide with the meal.
Similar articles
-
Strict glycemic control in diabetic dogs with closed-loop intraperitoneal insulin infusion algorithm designed for an artificial endocrine pancreas.J Artif Organs. 2003;6(1):55-63. doi: 10.1007/s100470300009. J Artif Organs. 2003. PMID: 14598126
-
Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics.IEEE Trans Biomed Eng. 1989 Apr;36(4):479-86. doi: 10.1109/10.18755. IEEE Trans Biomed Eng. 1989. PMID: 2714828
-
A semiclosed-loop optimal control system for blood glucose level in diabetics.J Med Eng Technol. 2004 Sep-Oct;28(5):189-96. doi: 10.1080/03091900410001662332. J Med Eng Technol. 2004. PMID: 15370997
-
Continuous glucose monitoring and closed-loop systems.Diabet Med. 2006 Jan;23(1):1-12. doi: 10.1111/j.1464-5491.2005.01672.x. Diabet Med. 2006. PMID: 16409558 Review.
-
Closed-loop insulin delivery - what lies between where we are and where we are going?Expert Opin Drug Deliv. 2005 Mar;2(2):353-62. doi: 10.1517/17425247.2.2.353. Expert Opin Drug Deliv. 2005. PMID: 16296759 Review.
Cited by
-
Sliding-mode-based controllers for automation of blood glucose concentration for type 1 diabetes.IET Syst Biol. 2021 Apr;15(2):72-82. doi: 10.1049/syb2.12015. IET Syst Biol. 2021. PMID: 33780148 Free PMC article.
-
The future of open- and closed-loop insulin delivery systems.J Pharm Pharmacol. 2008 Jan;60(1):1-13. doi: 10.1211/jpp.60.1.0001. J Pharm Pharmacol. 2008. PMID: 18088499 Free PMC article. Review.
-
Linear quadratic gaussian-based closed-loop control of type 1 diabetes.J Diabetes Sci Technol. 2007 Nov;1(6):834-41. doi: 10.1177/193229680700100606. J Diabetes Sci Technol. 2007. PMID: 19756210 Free PMC article.
-
Multi-objective blood glucose control for type 1 diabetes.Med Biol Eng Comput. 2009 Mar;47(3):343-52. doi: 10.1007/s11517-009-0453-0. Epub 2009 Feb 13. Med Biol Eng Comput. 2009. PMID: 19214613
-
Performance Analysis of Fuzzy-PID Controller for Blood Glucose Regulation in Type-1 Diabetic Patients.J Med Syst. 2016 Dec;40(12):254. doi: 10.1007/s10916-016-0602-6. Epub 2016 Oct 6. J Med Syst. 2016. PMID: 27714563
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical