Contrast and scatter in x-ray imaging
- PMID: 2028065
- DOI: 10.1148/radiographics.11.2.2028065
Contrast and scatter in x-ray imaging
Abstract
The effect of scattered radiation on x-ray image contrast is reviewed. Without scatter control, the information content of x-ray images is severely compromised. Typical grid performance in general radiography and mammography and grid selection considerations are presented. Contrast can be significantly improved and patient dose reduced if more efficient methods of scatter control can be developed. This can be accomplished in chest radiography with scanning slit and improved grid techniques, in mammography with multiple scanning slit techniques, and in abdominal radiography with scanning grid techniques.
Similar articles
-
Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems.Phys Med Biol. 2007 Aug 21;52(16):4863-80. doi: 10.1088/0031-9155/52/16/010. Epub 2007 Jul 30. Phys Med Biol. 2007. PMID: 17671340
-
Scanning multiple slit assembly: a practical and efficient device to reduce scatter.AJR Am J Roentgenol. 1977 Sep;129(3):497-501. doi: 10.2214/ajr.129.3.497. AJR Am J Roentgenol. 1977. PMID: 409206
-
[Effects of high-strip density anti-scatter grid on image quality and radiation dose].Rofo. 1997 Jun;166(6):475-80. doi: 10.1055/s-2007-1015462. Rofo. 1997. PMID: 9272997 German.
-
Electronic scanning-slit fluorography.Acta Radiol Suppl. 1989;373:1-48. Acta Radiol Suppl. 1989. PMID: 2488063 Review.
-
The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review.Eur J Radiol. 2023 Jan;158:110600. doi: 10.1016/j.ejrad.2022.110600. Epub 2022 Nov 17. Eur J Radiol. 2023. PMID: 36444818
Cited by
-
Enhanced visualization of mobile chest X-ray images in the intensive care setting using software scatter correction.Acta Radiol. 2023 Feb;64(2):563-571. doi: 10.1177/02841851221087631. Epub 2022 Mar 15. Acta Radiol. 2023. PMID: 35291841 Free PMC article.
-
An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.IEEE Trans Med Imaging. 2006 Apr;25(4):496-502. doi: 10.1109/TMI.2006.870896. IEEE Trans Med Imaging. 2006. PMID: 16608064 Free PMC article.
-
Real time implementation of anti-scatter grid artifact elimination method for high resolution x-ray imaging CMOS detectors using Graphics Processing Units (GPUs).Proc SPIE Int Soc Opt Eng. 2017 Feb 11;10132:101325Q. doi: 10.1117/12.2254120. Epub 2017 Mar 9. Proc SPIE Int Soc Opt Eng. 2017. PMID: 28659654 Free PMC article.
-
Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.Med Phys. 2007 Jul;34(7):2718-29. doi: 10.1118/1.2739805. Med Phys. 2007. PMID: 17821980 Free PMC article.
-
Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors.Proc SPIE Int Soc Opt Eng. 2015;9412:941243. doi: 10.1117/12.2081430. Epub 2015 Mar 18. Proc SPIE Int Soc Opt Eng. 2015. PMID: 26877578 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources