Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1991 Mar;16(3 Suppl):S170-5.
doi: 10.1097/00007632-199103001-00025.

Reconstruction of failed lumbar surgery with narrow AO DCP plates for spinal arthrodesis

Affiliations

Reconstruction of failed lumbar surgery with narrow AO DCP plates for spinal arthrodesis

J Thalgott et al. Spine (Phila Pa 1976). 1991 Mar.

Abstract

Forty-five patients underwent surgical reconstruction with transpedicular fixation of the lumbar spine with narrow AO DCP plates. Preoperatively, all patients underwent spinal imaging with either magnetic resonance imaging, computed tomography, or myelogram as well as provocative discography to determine the location and the number of symptomatic segments. The minimum follow-up in this series was 2 years. The determination of solid posterior fusion in the presence of plate instrumentation was difficult. The patients in the series were classified as having 1) solid fusion; 2) radiographic flaws within the posterolateral fusion without implant failure; or 3) frank pseudarthrosis with implant failure. Thirty-six (80%) of the patients had a solid fusion, 9 of whom required an additional anterior interbody fusion to obtain symptom control. Twenty percent of the patients in the series had radiographic evidence of reabsorption without implant failure. Four patients in the series (8.8%) had screw breakage, three of which required anterior interbody fusions. The highest rate of reabsorption and pseudarthrosis implant failure was in the 12 patients who had three-level instrumentation; 33% of these patients required anterior interbody fusion to obtain a solid arthrodesis. The average preoperative pain scale was 8.9, and the average postoperative pain scale was a 3.3. Twenty-two patients in the series were cigarette smokers and had a slightly lower fusion rate than non-smokers. They did, however, have a higher use of narcotics after surgery. Forty percent of the patients in this series continued to have radiculopathy after their reconstruction. This study demonstrates the utility of transpedicular fixation in salvage lumbar surgery in obtaining a solid arthrodesis with a beneficial clinical result. Anterior interbody fusions are highly successful in the management of pseudarthrosis and implant failure after transpedicular instrumentation.

PubMed Disclaimer

LinkOut - more resources