Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Apr;48(4):561-8.
doi: 10.1515/CCLM.2010.104.

A methodological reappraisal of total and high molecular weight adiponectin determination in human peripheral circulation: comparison of four immunometric assays

Affiliations
Comparative Study

A methodological reappraisal of total and high molecular weight adiponectin determination in human peripheral circulation: comparison of four immunometric assays

Chiara Caselli et al. Clin Chem Lab Med. 2010 Apr.

Abstract

Background: Adiponectin, present in different multimeric forms in circulation, is increasingly used in clinical settings as a cardiometabolic marker. The development of several commercially available enzyme-linked immunosorbent assays (ELISA) has allowed for the widespread measurement of adiponectin in research as well as in clinical practice. The comparative performance of these assays is thus an issue of major relevance.

Methods: The analytical performance of four different ELISAs (LINCO, B-Bridge, SPIbio and ALPCO) was evaluated. Samples from 102 cardiac patients and 40 healthy subjects were tested using LINCO and ALPCO. The latter is able to measure the concentrations of multimers. For the multimer assay, an error propagation study was performed. A subset of subjects was tested by all four ELISAs for comparison purposes.

Results: Bland-Altman plots revealed differences between the results of the four ELISAs, mainly for ALPCO. However, a strong correlation between the different ELISAs (ALPCO, r=0.83; B-Bridge, r=0.98; SPIbio, r=0.91 vs. LINCO) was observed. Total adiponectin measured by LINCO showed a better association with cardiac disease [receiver-operating characteristic (ROC) curves] than total and high molecular weight adiponectin measured by ALPCO.

Conclusions: The results of this study contribute to a better understanding of the methodological features of the several ELISAs, and help in the evaluation and comparison of the relative results.