. 2010 Jun;17(3):398-404.
doi: 10.1007/s12350-009-9169-7. Epub 2010 Mar 19.

Relation of left-ventricular dyssynchrony by phase analysis of gated SPECT images and cardiovascular events in patients with implantable cardiac defibrillators

Affiliations
Free article

Relation of left-ventricular dyssynchrony by phase analysis of gated SPECT images and cardiovascular events in patients with implantable cardiac defibrillators

Wael A Aljaroudi et al. J Nucl Cardiol. 2010 Jun.
Free article

Abstract

Background: Left-ventricular (LV) dyssynchrony could be measured by gated SPECT myocardial perfusion imaging (MPI). This study examined the relation between the degree of dyssynchrony and outcome in patients with implantable cardiac defibrillators (ICDs).

Methods and results: We studied 70 patients with ICD and LV ejection fraction (EF) <.40 by gated MPI (performed within 6 weeks of the device implantation). The images were re-processed using phase analysis to derive phase standard deviation (SD) and histogram bandwidth. All-cause mortality and appropriate ICD shocks were identified as the primary endpoint. There were 87% men, aged 62 +/- 11 years. The EF was 26 +/- 8% (range 12%-39%). The phase SD was 51 degrees +/- 20 degrees (range 12 degrees -99 degrees ) and the histogram bandwidth was 157 degrees +/- 72 degrees (range 21 degrees -327 degrees ). The SD and bandwidth were significantly greater than corresponding values in patients with normal EF (15.8 +/- 11.8 degrees and 42.0 +/- 28.4 degrees , respectively, P < .0001, each). At 1 year, 8 patients (11%) died or had shocks. The patients with events had higher phase SD than those without events (60 +/- 5 degrees vs 50 +/- 21 degrees , P = .002). The histogram bandwidth was also higher in those with events (185 +/- 37 vs 154 +/- 75, P = .07). All patients with event had a phase SD >or= 50 degrees , while none of the patients with a phase SD < 50 degrees (N = 26) had an event (P = .02).

Conclusions: The severity of LV dyssynchrony by phase analysis in patients with LV dysfunction, and ICD is associated with increased risk of death and appropriate ICD shock; a phase SD < 50 degrees was associated with no events at 1 year.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. J Am Coll Cardiol. 2005 Dec 20;46(12):2153-67 - PubMed
    1. J Nucl Cardiol. 2009 Nov-Dec;16(6):895-903 - PubMed
    1. J Am Coll Cardiol. 2007 Apr 24;49(16):1708-14 - PubMed
    1. Am J Cardiol. 2006 Jul 15;98(2):230-5 - PubMed
    1. N Engl J Med. 2002 Mar 21;346(12):877-83 - PubMed

LinkOut - more resources