High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?
- PMID: 20308495
- DOI: 10.2214/AJR.09.3482
High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?
Abstract
Objective: The purpose of this study was to prospectively evaluate the average heart rate and heart rate variability required for diagnostic imaging of the coronary arteries with high-pitch dual-source CT angiography of the thoracic and thoracoabdominal aorta.
Subjects and methods: One hundred consecutively registered patients (82 men, 18 women; mean age, 68 +/- 13 years) underwent clinically indicated CT angiography of the thoracic (n = 33) and thoracoabdominal (n = 67) aorta with a dual-source 128-MDCT scanner in ECG-synchronized high-pitch (pitch, 3.2) data acquisition mode. No beta-blockers were administered. The image quality of the coronary arteries was graded on a 3-point scale by two independent blinded readers. The average heart rate and heart rate variability before data acquisition were noted. Effective radiation doses were calculated.
Results: Interobserver agreement on grade of image quality for the 1,414 coronary segments evaluated by both observers was good (kappa = 0.68). Diagnostic image quality was found for 1,375 of the 1,414 segments (97.2%) in 83 of 100 patients (83%). In 17% of the patients, image quality was nondiagnostic for at least one coronary artery segment. Average heart rate and heart rate variability (each p < 0.05) were significantly higher in patients with at least one nondiagnostic coronary segment compared with those without. All patients with an average heart rate less than 63 beats/min and heart rate variability less than 1.2 beats/min had diagnostic image quality in all coronary segments. Effective radiation doses were 2.3 +/- 0.3 mSv for thoracic and 4.4 +/- 0.5 mSv for thoracoabdominal CT angiography. The average scan times were 0.88 +/- 0.06 second for thoracic and 1.67 +/- 0.15 seconds for thoracoabdominal CT angiography.
Conclusion: For patients with an average heart rate less than 63 beats/min and heart rate variability less than 1.2 beats/min, dual-source CT angiography of the thoracoabdominal aorta at a high pitch of 3.2 delivers diagnostic depiction of the coronary arteries at a low radiation dose.
Similar articles
-
High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy.JACC Cardiovasc Imaging. 2011 Jun;4(6):602-9. doi: 10.1016/j.jcmg.2011.02.014. JACC Cardiovasc Imaging. 2011. PMID: 21679894
-
Thoracic aorta: prospective electrocardiographically triggered CT angiography with dual-source CT--feasibility, image quality, and dose reduction.Radiology. 2010 Apr;255(1):207-17. doi: 10.1148/radiol.09090860. Epub 2010 Feb 16. Radiology. 2010. PMID: 20160003 Clinical Trial.
-
Image quality and radiation exposure using different low-dose scan protocols in dual-source CT coronary angiography: randomized study.Radiology. 2011 Dec;261(3):779-86. doi: 10.1148/radiol.11110606. Epub 2011 Oct 3. Radiology. 2011. PMID: 21969666 Clinical Trial.
-
Safety, efficacy, and indications of beta-adrenergic receptor blockade to reduce heart rate prior to coronary CT angiography.Radiology. 2010 Dec;257(3):614-23. doi: 10.1148/radiol.10100140. Radiology. 2010. PMID: 21084413 Review.
-
Radiation dose from coronary CT angiography: five years of progress.J Cardiovasc Comput Tomogr. 2010 Nov-Dec;4(6):365-74. doi: 10.1016/j.jcct.2010.09.002. Epub 2010 Sep 16. J Cardiovasc Comput Tomogr. 2010. PMID: 21130064 Review.
Cited by
-
The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography.J Cardiothorac Surg. 2013 Dec 12;8:228. doi: 10.1186/1749-8090-8-228. J Cardiothorac Surg. 2013. PMID: 24330784 Free PMC article. Clinical Trial.
-
Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.Eur Radiol. 2014 May;24(5):990-7. doi: 10.1007/s00330-014-3120-2. Epub 2014 Feb 28. Eur Radiol. 2014. PMID: 24573567 Clinical Trial.
-
Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.Eur Radiol. 2014 Nov;24(11):2677-84. doi: 10.1007/s00330-014-3312-9. Epub 2014 Jul 24. Eur Radiol. 2014. PMID: 25052076 Clinical Trial.
-
Clinical outcomes of a CT protocol for simultaneous examination of the aorta and coronary artery in patients with aortic aneurysm.Front Cardiovasc Med. 2023 Apr 12;10:1144444. doi: 10.3389/fcvm.2023.1144444. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37123481 Free PMC article.
-
Ultrafast imaging of the entire chest without ECG synchronisation or beta-blockade: to what extent can we analyse the coronary arteries?Insights Imaging. 2012 Feb;3(1):73-9. doi: 10.1007/s13244-011-0133-0. Epub 2011 Nov 26. Insights Imaging. 2012. PMID: 22696000 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources