The introduction of automated dispensing and injection during PET procedures: a step in the optimisation of extremity doses and whole-body doses of nuclear medicine staff
- PMID: 20335185
- DOI: 10.1093/rpd/ncq110
The introduction of automated dispensing and injection during PET procedures: a step in the optimisation of extremity doses and whole-body doses of nuclear medicine staff
Abstract
Significant staff exposure is generally expected during PET-and PET/CT applications. Whole-body doses as well as extremity doses are usually higher per procedure compared with SPECT applications. Dispensing individual patient doses and manual injection involves high extremity doses even when heavy weighted syringe shields are used. In some cases the external radiation causes an exposure to the fingertips of more than 500 mSv y(-1), which is the yearly limit. Whole-body doses per procedure are relatively lower compared with extremity doses and are generally spread over the entire procedure (Guillet, B., Quentin, P., Waultier, S., Bourrelly, M., Pisano, P. and Mundler, O. Technologist radiation exposure in routine clinical practice with 18F-FDG PET. J. Nucl. Med. Technol. 33, 175-179 (2005). Optimisation of the individual workload is often used to restrict staff doses, but many PET centres face the need for further optimisation to reduce the staff doses to an acceptable level. During this study the effect of the use of an automated dispensing and injection system for (18)FDG on whole-body doses and extremity doses was evaluated. Detailed dosimetric studies using thermoluminescent and direct ion storage dosimetry were carried out before and after the introduction of this system. The results show that the extremity doses can be reduced by more than 95 % up to a mean level of 10 muSv per handled GBq. At the same time, whole-body doses can be halved during injection of the tracer. This results in a dose reduction of 20 % during the entire procedure of injection, escorting and positioning. In this way, the study shows that with the use of automated dispensing and injection a considerable staff dose reduction can be obtained.
Similar articles
-
Technologist radiation exposure in routine clinical practice with 18F-FDG PET.J Nucl Med Technol. 2005 Sep;33(3):175-9. J Nucl Med Technol. 2005. PMID: 16145226
-
Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia.Radiat Prot Dosimetry. 2014 Dec;162(4):577-85. doi: 10.1093/rpd/ncu001. Epub 2014 Jan 23. Radiat Prot Dosimetry. 2014. PMID: 24464817
-
Extremity dosimetry for radiation workers handling unsealed radionuclides in nuclear medicine departments in India.Health Phys. 2007 Feb;92(2):112-8. doi: 10.1097/01.HP.0000236787.25865.fb. Health Phys. 2007. PMID: 17220712
-
An overview on extremity dosimetry in medical applications.Radiat Prot Dosimetry. 2008;129(1-3):350-5. doi: 10.1093/rpd/ncn149. Epub 2008 Apr 29. Radiat Prot Dosimetry. 2008. PMID: 18448440 Review.
-
Trends in radiation protection of positron emission tomography/computed tomography imaging.Ann ICRP. 2015 Jun;44(1 Suppl):259-75. doi: 10.1177/0146645314551671. Epub 2014 Nov 3. Ann ICRP. 2015. PMID: 25915553 Review.
Cited by
-
Optimizing Radiation Protection in PET/CT Examinations: Reducing Occupational Exposure During Patient Positioning.Cureus. 2024 Dec 3;16(12):e75052. doi: 10.7759/cureus.75052. eCollection 2024 Dec. Cureus. 2024. PMID: 39749070 Free PMC article.
-
Validation of a new protocol for ¹⁸F-FDG infusion using an automatic combined dispenser and injector system.Eur J Nucl Med Mol Imaging. 2012 Nov;39(11):1720-9. doi: 10.1007/s00259-012-2174-0. Epub 2012 Jun 28. Eur J Nucl Med Mol Imaging. 2012. PMID: 22740098
-
Occupational radiation exposure assessment during the management of [68Ga]Ga-DOTA-TOC.EJNMMI Phys. 2022 Oct 29;9(1):75. doi: 10.1186/s40658-022-00505-8. EJNMMI Phys. 2022. PMID: 36309605 Free PMC article.
-
Exposure Doses to Technologists Working in 7 PET/CT Departments.Dose Response. 2020 Jul 9;18(3):1559325820938288. doi: 10.1177/1559325820938288. eCollection 2020 Jul-Sep. Dose Response. 2020. PMID: 32694961 Free PMC article.
-
The potential advantages and workflow challenges of long axial field of view PET/CT.J Med Radiat Sci. 2023 Sep;70(3):310-318. doi: 10.1002/jmrs.686. Epub 2023 May 8. J Med Radiat Sci. 2023. PMID: 37156564 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials